Bosch FAP-OC 500Series Installatiehandleiding - Pagina 7

Blader online of download pdf Installatiehandleiding voor {categorie_naam} Bosch FAP-OC 500Series. Bosch FAP-OC 500Series 28 pagina's. Built-in wall ovens
Ook voor Bosch FAP-OC 500Series: Handleiding voor installatie-instructies (21 pagina's), Gebruiksaanwijzing (40 pagina's), Installatiehandleiding (6 pagina's), Productinformatie (40 pagina's), Installatiehandleiding (28 pagina's), Gebruikershandleiding (48 pagina's), Gebruikershandleiding (48 pagina's), Installatiehandleiding (28 pagina's), Gebruiks- en onderhoudshandleiding (44 pagina's), Installatiehandleiding (32 pagina's), Gebruiks- en onderhoudshandleiding / Installatie-instructies (40 pagina's), Snelle referentiehandleiding (4 pagina's), Gebruiks- en onderhoudshandleiding (27 pagina's), Installatiehandleiding (24 pagina's), Installatiehandleiding (32 pagina's), Gebruiks- en onderhoudshandleiding (24 pagina's), Servicehandleiding (41 pagina's), Gebruiks- en onderhoudshandleiding (21 pagina's), Installatiehandleiding (32 pagina's), Servicehandleiding (36 pagina's), Installatiehandleiding (32 pagina's), Snelstart- en veiligheidshandleiding (13 pagina's)

Bosch FAP-OC 500Series Installatiehandleiding
* Flush installation requires a
22
/
" (560 mm) wide x 22
1
16
plate underneath the unit body.

Install Appliance

Electrical Installation

The ovens is dual rated, designed to be connected to
either 208/240V AC, 60 Hz, 4 wire, single-phase power
supply.
Model
Dedicated
circuit
required
HBE5452UC
20 AMP
The electrical supply should be a 4-wire single-phase AC.
Install a suitable conduit box (not furnished). An
appropriately-sized, UL-listed conduit connector must be
used to correctly attach the conduit to the junction box.
NOTICE: Local Codes may vary; installation, electrical
connections and grounding must comply with all
applicable local codes.
If local codes permit grounding through the electrical
supply neutral, connect both the white neutral wire and
the bare ground wire from the oven to the white neutral
electrical supply wire.
CAUTION
9
The appliance must be disconnected from the
power supply during all installation work.
The appliance must only be connected with the
power cable provided.
Protection against contact must be ensured by
the installation.
Electrical Connection
The four-wire connection is preferred, but where local
codes permit, the three wire connection is also
acceptable.
Four-wire Connection
Ungrounded Neutral
/
" (5 mm) high x
3
16
/
" (581 mm) deep base-
7
8
Watts @
Watts @
240V
208V
4000
3000
Connect the red oven wire to the red electrical supply
wire (hot wire).
Connect the black oven wire to the black electrical
supply wire (hot wire).
Connect the green ground oven wire to the bare or
green ground electrical supply wire.
Three-wire Connection
Grounded Neutral
Connect red wire from oven to red wire in junction box.
Connect black wire from oven to black wire in junction
box.
Connect green ground wire from oven to white, green
or bare neutral wire in junction box.
The conduit cable, where connected at the oven, swivels.
Rotate conduit cable upward (or downward) and direct
through hole prepared in cabinet to attach to junction
box.
To maintain serviceability, the flex conduit must not be
shortened and should be routed to permit temporary
removal of the oven.
7