Dramm pulsFOG Turbo Aanvullende handleiding - Pagina 6

Blader online of download pdf Aanvullende handleiding voor {categorie_naam} Dramm pulsFOG Turbo. Dramm pulsFOG Turbo 8 pagina's. Ulv hybrid sprayer

Mix with the appropriate amount of carrier and water for 15,000 square feet. Adjust the carrier and
water based on the same ratio above.
NOTE: If the chemical you are using provides an area rate on the label in addition to the 100 gallon
rate, USE THIS INSTEAD OF CALCULATING as shown above.
Example:
The label states "Use 10 oz per acre of CHEMICAL Z."
One acre is 43,560 square feet.
Divide 10 oz/43,560 sq ft (to determine how much per sq ft.) = 0.00023 oz/sq ft.
Multiply by the number of sq ft to be covered. 0.00023 x 15,000 sq ft = 3.4 oz
Mix into the appropriate amount of carrier and water for 15,000 square feet. Adjust the carrier and
water based on the previous example.
The chart on the following page describes how to mix carrier solutions as well as converts chemical
rates at the 0.40 rate.
NEXT: Determine the amount of spray solution to use for your application:
Ultra Low Volume (space treatment) Application
The Turbo ULV has a tank capacity of 5 liters. Up to a maximum of 25,000 square feet can be treated
with the Turbo ULV using the ULV method.
Under this method, use 1 liter of FINISHED SOLUTION to treat 5,000 square feet. Mixing instructions
for solution are described in a chart on the following page.
Targeted Low Volume (directed treatment) Application
The Turbo ULV has a tank capacity of 5 liters. Up to a maximum of 5,000 square feet can be treated
with the Turbo ULV using the Targeted Low Volume method.
Under this method, use 1 liter of FINISHED SOLUTION to treat 1,000 square feet. Mixing instructions
for solution are described in a chart on the following page.
Dramm Turbo ULV Manual Supplement 9/18