Acumen
E & V - 220V

Section 8 - Accessing Internal Low-Voltage Control Unit

PLEASE NOTE: Applies ONLY if Unit is built into case.
1. Using a 3/32"
Hex Wrench, remove the screw from the wiring access door on the motor end of the case.
(3mm)
2. Remove the wiring access door and locate the Low Voltage Wiring Whip.
3. Make appropriate Low Voltage wiring connections
Low Voltage connection hole on the either the top or back of case.
4. Replace the access door and secure with screw using 3/32"
Internal LVC-IV - Single or Multiple Projection Screen Wiring Diagram
Internal LVC-IV - Single or Multiple Projection Screen Wiring Diagram
INTERNAL SCREEN WIRING
Green/Yellow
(Motor Ground)
Black (Up)
Brown (Down)
Blue (Common)
GND
N
To
L1
230 VAC
Line
. Low Voltage wiring should exit through the
(see Section 8)
Hex Wrench.
(3mm)
Two electrical connection holes
are included in the screen housing
to separate Low-Voltage
and High-Voltage Wiring.
Low Voltage Wire
Remove
Access
Door
Green/Yellow (Ground)
Red-to screen (directional)
Brown-to screen (directional)
White -Common to screen & 230V AC Neutral
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low-voltage wiring by others
Factory wiring

(LVC-IV)

.
(closest to the motor endcap)
Connection Holes
Low Voltage
Figure 13
Receiver
Button
Electrical
High Voltage
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules.*
RS232/485
Inputs/Outputs
IR Eye Input
Low-Voltage
Trigger
4-28 VDC
page 9 of 12
Wall Switch
*A maximum of six (6)
LVC-IV modules can be
linked together.