Draper Premier XL 220 Gebruiksaanwijzing - Pagina 4
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} Draper Premier XL 220. Draper Premier XL 220 7 pagina's. Electric projection screen
Premier XL
®
Electric Projection Screen
Section 5 - Limit Adjustments
Please Note: Screen limits are factory set for optimum performance of screen. Any adjustment of these limits
could void warranty. Please check with Draper prior to resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen
may be severely damaged if viewing surface is allowed to run too far up or too far down.
CAUTION: Be sure all switches are in "off" position before adjusting limit
made from wall switch)
1. Connect ILT switch to motor via terminal blocks, or via modular port using four conductor modular cable. When using
modular cable, cable connectors MUST NOT be crimped in reverse, as with standard telephone cable.
2. Set slide switch to lower position. Press and hold DOWN button on switch to move viewing surface to desired lower
limit. If screen moves in opposite direction, release DOWN button and press and hold down STOP button for four
seconds. This will reverse operation of UP and DOWN switches.
3. Move slider switch into center position. Wait a couple of seconds.
Please Note: Moving slider switch from down to up in one motion sets two limits in same position.
4. Set slide switch to higher position. Move viewing surface to desired upper limit by pressing and holding UP button on
wall switch.
5. Return slide switch to center position to return to normal operation.
Section 6 - Limit Adjustments
Please Note: Screen limits are factory set for optimum performance of screen. Any adjustment of these limits could void warranty. Please check with Draper prior to
resetting screen limits.
CAUTION: Always be prepared to shut screen off manually when new adjustment is being tested. Screen may be severely damaged if viewing surface is allowed to run
too far up or too far down.
CAUTION: Be sure all switches are in "off" position before adjusting limit switches.
1. Adjusting "fully up" position —If you do, however, "Up" stopping position may be adjusted by turning yellow limit switch adjustment socket. The yellow socket is located on left end
of screen roller and is accessible to a screwdriver/Allen wrench
clockwise will cause surface to stop farther out of case. One full revolution of socket will alter stopping position of viewing surface by approximately 38.1mm.
2. Adjusting "fully down" position — "Down" stopping position may be adjusted by turning white limit switch adjustment socket. The white socket is located on left end of screen roller
and is accessible to a screwdriver/Allen wrench
viewing surface, causing it to stop in a less extended position. At no time should viewing surface be unrolled enough to expose any part of screen roller.
/ Targa XL
®
(Motor with Internal Low Voltage Controller)
(Standard Motor)
(4mm or
5
/
32
(4mm or
5
/
"). Turning socket counterclockwise will allow viewing surface to run farther down. Turning it clockwise will shorten
32
220V
switches.(Height adjustments are
Please Note: 5V DC must be
connected in order to set
limits using wall switch.
"). Turning socket counterclockwise will allow viewing surface to retract farther into case. Turning it
page 4 of 7
FUNCTION
POSITION
Set LOWER limit
DOWN
Set UPPER limit
UP
Normal Operation
CENTER
Back View of Wall Switch
To Motor
with
Internal
Low Voltage
Slide
Switch
C
o
m
+
m
5V
o
To Motor
DC
n
with
Internal
Low Voltage
D
o
U
w
p
n