AirStage ASUB24RLAV Bedieningshandleiding - Pagina 4
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} AirStage ASUB24RLAV. AirStage ASUB24RLAV 8 pagina's. Indoor unit (wall mounted type)
Ook voor AirStage ASUB24RLAV: Installatiehandleiding (17 pagina's)
Temperature and humidity range
●
The temperature and humidity required for operating this product is as
shown in the following table.
Cooling/Dry Mode
Outdoor
Please refer to the specifi cation of outdoor units.
temperature
Indoor
About 64 to 90 °F DB
temperature
(18 to 32 °C DB)
Indoor humidity
About 80% or less
●
If the air conditioner is operated under higher temperature conditions
than those listed, the built-in protection circuit may operate to prevent
internal circuit damage. Also, during Cooling and Dry modes, if the unit
is used under conditions of lower temperature than those listed above,
the heat-exchanger may freeze, leading to water leakage and other
damage.
●
If the unit is used for long periods under high-humidity conditions,
condensation may form on the surface of the indoor unit, and drip onto
the fl oor or other objects underneath.
●
Do not use this unit for any purposes other than the Cooling, Heating,
Dehumidifying, and air-circulation of rooms in ordinary dwellings.
CLEANING AND CARE
CAUTION!
●
Before cleaning the unit, be sure to stop the unit and disconnect the
power supply.
●
Do not stand on an unstable platform when cleaning.
●
When removing and replacing the air fi lters, be sure not to touch the
heat exchanger, as personal injury may result.
●
Be sure the intake grille is installed securely.
●
When cleaning the unit's body, do not use water hotter than 104 °F
(40 °C), harsh abrasive cleansers, or volatile agents like benzene or
thinner.
●
If dirt is allowed to accumulate on the air fi lter, airfl ow will be reduced,
lowering operating effi ciency and increasing noise.
During periods of normal use, the air fi lters should be cleaned every 2
weeks.
Cleaning the intake grille and the air fi lter
1.
Remove the intake grille and the air fi lter.
(1) Place your fi ngers at both lower ends of the grille panel, and lift
forward.
(2) Pull down the knob.
(3) Open the intake grille, and lift the intake grille upward, until the axle
at the top of the intake grille is removed.
(4) Lift up the air fi lter's handle, disconnect the 2 lower tabs, and pull out
the air fi lter.
Intake grille
(3)
(3)
(1)
(1)
Air fi lter handle
Hooks (2 places)
En-3
Heating Mode
About 50 to 86 °F DB
(10 to 30 °C DB)
Mounting
shaft
Knob
(2)
(2)
2.
Cleaning
(1) Cleaning the intake grill
Remove dust with a vacuum cleaner, wash the grille with warm water,
and then dry with a clean and soft cloth.
(2) Cleaning the air fi lter
Remove dust with a vacuum cleaner or by washing. After washing, be
sure to allow it to dry thoroughly in a shady place before reinstalling.
3.
Replace the intake grille and the air fi lter.
(1) Align the sides of the air fi lter with the panel, and push in fully, making
sure the 2 lower tabs are returned properly to their holes in the panel.
(2) The fi xing axle of the intake grille is installed on the front panel.
(3) Lay down the intake grille.
(1)
(2)
Intake grille
Intake grille
(2)
Air cleaning & deodorizing fi lter installation
(1) Open the intake grille and remove the air fi lters.
(2) Set the Air cleaning & deodorizing fi lter into the Air cleaning & de-
odorizing fi lter frame.
(3) Engage the 6 latches of the Air cleaning & deodorizing fi lter frame
with the 6 hooks at the rear of the air fi lters.
(4) Install the 2 air fi lters and close the intake grille.
Air cleaning & deodorizing fi lter
Hook (6 places at the rear)
Cleaning body
Wash the body with warm water, and then dry with a clean and soft cloth.
When not using for an extended period
Leave the breaker on for at least 12 hours before starting operation when
it is to be used again.
(1)
Hooks (2 places)
Mounting shaft
Bearing
Knob
Mounting
shaft
Knob
(2)
Air cleaning & deodorizing
fi lter frame
Latch (6 places)