Alemlube 339000 Technische handleiding eigenaar - Pagina 5

Blader online of download pdf Technische handleiding eigenaar voor {categorie_naam} Alemlube 339000. Alemlube 339000 7 pagina's. 240v diesel transfer pump

TROUBLE SHOOTING
Condition
The engine does not work
or runs very slowly
The engine works but even
running there is no pumping
effect or it is very low
The thermo probe starts working
The pump body loses diesel

Overall Dimensions

NSW/ACT
QLD/PNG
TEL: (02) 9677 1555
TEL: (07) 3204 9166
FAX: (02) 9675 1155
FAX: (07) 3204 1224
OWNER'S TECHNICAL MANUAL
240V Diesel Transfer Pump
Possible Cause
There is no voltage
The rotor is locked
The condenser is not efficacious
Voltage drop or low rate
The filter is obstructed
The foot valve is obstructed
The suction tube is obstructed
Suction too high
Presence of air during the suction
Working in by-pass
The by-pass valve is locked
The suction tube narrows
The rotor is obstructed
The electric engine is overheating
The rotor is locked
The electric engine is damaged
Seals are damaged
VIC/TAS
TEL: (03) 8787 8288
FAX: (03) 8787 8266
Visit our website at
www.alemlube.com.au
Corrective Action
Check cut-outs and net voltage
Remove the cover and check and/or
clean the rotor
Replace the component
Bring the voltage to normal values
Clean the filter
Clean or replace the valve
Clean or replace the suction tube
Draw up the pump to the diesel static level
Check the connections tightness
Reduce the charge losses of the circuit
Unlock, clean or change the by-pass valve
Use right tubes during depression process
Clean the rotor and pump body
Check voltage and ventilation
The pumped diesel is not fluid enough
Unlock the rotor and clean the pump body
Ask for authorised staff help
Replace seals
WA
SA/NT
TEL: (08) 9302 4199
TEL: (08) 8241 7111
FAX: (08) 9303 2095
FAX: (08) 8241 7011
or
www.alemlube.co.nz
339000
NZ
TEL: (09) 447 1007
FAX: (09) 447 1008
5