Continue pressing the
button to examine the following
information recorded during the fault cycle.
• Line Voltage
• Motor Amps (OK or Low)
• Ignitor Amps (OK or Low)
• Valve Amps (OK or Low)
• Recycle (Yes or No)
• Burn Time
• Flame Delay
On any fault detail screen listed above, the
pressed to view the same data in the previous fault cycle. For
example, if in Fault 1 (the most recent fault), the Ignitor Amps
E
were low, by pressing the
2 (the previous fault cycle) will be displayed.
To Exit Fault History: Press and hold the
ton for 3 seconds at any time.
Status Icons
Status Icons will appear at the top of the 70200 display to indicate the control's current operating condition.
POWER
Indicates that the control is powered (flashes if voltage is too low or too high)
TT
Displayed when the TT terminals are physically jumpered, jumpered in the set-up menu, or when thermostat
is calling for heat.
LIMIT
Indicates that the burner limit circuit is powered.
IGNITOR
Indicates that the ignitor is energized (flashes if ignitor not detected)
MOTOR
Indicates that the motor is energized (flashes if motor not detected)
VALVE
Indicates that the valve is energized (on entry to pump prime will flash if not detected)
BV
Indicates vent input is active (when vent input is selected)
FAULT
Flashes in unison with other status icons indicating a problem exists in that area
FLAME
Indicates the CAD cell is sensing flame
Service and Troubleshooting
Last Fault Display: When the control is reset from a lockout
condition, if the burner resumes normal operation, the screen
will toggle the last fault and its cause for five days (longer du-
ration if control is not wired for constant power). This feature
is designed to allow the service technician to easily see what
caused the condition in the event the homeowner reset the
control prior to his arrival. The screen will alternate between
displaying what the last fault was and displaying how to clear
the message hold ESC for 3 seconds.
Last Fault
No Flame Chk Ign
To Clear Message
Hold
3 Sec
Display Voltage and Current: Press
display real time voltage and current.
Amps = 7 mA
Line = 115 VAC
Carlin Combustion Technology, Inc.
E
button can be
button, the Ignitor Amps in Fault
F
/ ESCAPE but-
Toggle
+
for 3 seconds to
Total/Run History
In addition to the Fault History (left),the 70200 also logs the
total run history of the control. To enter this menu, simultane-
E
F
ously press the
and
below will appear.
Total History
To Exit Hold
To Exit Total History: Press and hold the
ton for 3 seconds at any time.
H
Press
button to scroll through the history which includes:
• Total On Time
• Total Burn Time
• Total Burner Run Cycles
• Faults Cleared (cycles ago)
Lockout: If lockout occurs, the screen turns on, the fault icon
flashes and a fault message is displayed on the screen. To
Reset Push in and hold the red Reset button for 1 second,
then release. NOTE: Recycling power to the control will not
reset it from it from a lockout condition.
Two fault conditions result in an immediate lockout. These
include; Flame detected during pre-purge and flame failure
during Trial for Ignition. All other faults will result in a Recycle
(unless the Allowed Recycles is set to 'None' in the Set-up
Menu). A Recycle results in the burner shutting down for 60
seconds then resuming operation in Standby (if there is no
Call for Heat) or initiating the Operating Sequence above (if
there is a Call for Heat).
Latch-up: If the control locks out 3 times during a single Call
for Heat, Latch-Up will be displayed on screen.
To Reset the control after latch-up, press and hold the red
Reset button for 30 seconds. WARNING: Only a qualified
service technician should attempt to reset the control
after latch-up. The problem that caused the repeat lock-
outs must be corrected before returning the burner to
normal operation. NOTE: Recycling power to the control will
not reset it from it from a latch-up condition.
Service and Troubleshooting continued on next page.
7
buttons for 3 seconds. The display
/ ESCAPE but-
• Max Line Volts
• Min Line Volts
• Total Recycles