Carlin 60200FR Handleiding voor installatie en gebruik - Pagina 2

Blader online of download pdf Handleiding voor installatie en gebruik voor {categorie_naam} Carlin 60200FR. Carlin 60200FR 9 pagina's. Gas burner primary control
Ook voor Carlin 60200FR: Handleiding voor installatie en gebruik (8 pagina's)

Carlin 60200FR Handleiding voor installatie en gebruik
1. Warning – Do not attempt to confirm combustion simply by inspecting the flame visually. You must use combustion test instru-
ments. Failure to properly verify/adjust combustion could allow unsafe operation of the burner, resulting in severe personal injury,
death or substantial property damage. Refer to the burner manual for proper setup instructions.
2. Warning – Never test an ignitor by placing a screwdriver (or other metallic object) across the high voltage clips. Check ignitors only
by observing spark at appliance ignition electrodes, with fuel supply OFF. Using any other method could cause ignitor damage and
severe personal injury.
3. Danger – Fire, explosion, or carbon monoxide hazard. Water damage can lead to unreliable operation or cause the control to
malfunction which could lead to severe personal injury or death. Do not install the control module where it can get wet. Always
replace the control if it gets wet or if it has any signs of water residue.
4. Warning – Electrical shock hazard. To prevent electrical shock, death, or equipment damage, disconnect power supply before
installing or servicing control. Only qualified personnel may install or service this control in accordance with local codes and ordi-
nances. Read instructions completely before proceeding.
5. Warning – Electrical shock hazard. The ignition circuit of the control can produce over 10,000 volts which can cause severe injury
or death.
6. Warning – Frozen pipes/water damage. This is not a freeze protection device. Central heating systems are prone to shut down as
a result of power or fuel outages, safety related fault conditions or equipment failure. Installation of freeze protection monitoring or
other precautions are recommended for unattended dwellings in climates subject to sustain below-freezing temperatures.
7. Warning – All work must be performed by a qualified and licensed professional in accordance with all applicable codes and ordi-
nances.
8. Notice – Read these instructions completely before proceeding with the installation.
9. Notice – Retain these instructions for future reference.
10. Notice – All wiring must comply with the National Electric Code or any other state or local codes or regulations.
11. Danger – Carbon Monoxide Hazard. Improper application or use can result in dangerous flue products, such as carbon monox-
ide, which can escape into the living space causing severe injury or death. All venting must be checked for proper operation before
allowing the burner to run.
The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or
to important information concerning the life of the product.
Indicates presence of hazards that will cause
severe personal injury, death or substantial
property damage.
Indicates presence of hazards that will cause
severe personal injury, death or substantial
property damage.

Installing

The 60200FR control must be installed and serviced only by a qualified service technician.
Always disconnect power source before wiring to avoid electrical shock or damage to the control. All wiring must
comply with applicable codes and ordinances.

Mounting

The control may be mounted on a 4" x 4" junction box in any convenient location on the burner, furnace or wall. The
location must not exceed the ambient temperature limit, 140°F.
Carlin Combustion Technology, Inc.
W A R N I N G S

Hazard Definitions

2
Indicates presence of hazards that will cause
minor personal injury or property damage.
Indicates special instructions on installation,
operation or maintenance that are important
but not related to personal injury or property
damage.
MN60200FR1 070319