Fig. 6
OKCV 125 NTR, OKCV 160 NTR, OKCV 180 NTR, OKCV 200 NTR
Type
A
B
C
D
E
F
G
H
I
J
Type
Capacity
Max operating overpressure in the tank
Maximum operating pressure in the exchanger MPa
Electric connection of control elements
El.protection
Max temperature of HSW
Recommended HSW temperature
Max weight of the heater without heater
Exchanger heat surface
Rated thermal output at heating water
temperature of 80°C and flow 720 l/h
Time of heating by exchanger from 10°C to 60°Cmin
Rated thermal output at heating water
temperature of 80°C and flow 310 l/h
Time of heating by exchanger from 10°C to 60°Cmin
Heat losses
OKCV 125 NTR
OKCV 160 NTR
1046
1235
600
700
908
1008
524
524
184
230
513
650
200
200
559
559
350
350
225
225
OKCV 125 NTR
l
MPa
°C
°C
kg
2
m
W
W
kWh/24h
OKCV 180 NTR
1187
600
907
584
258
570
240
616
358
252
OKCV 160 NTR
125
152
1 PE-N 230V/50Hz
IP 44
55
65
0,7
0,7
15000
16800
37
35
8000
10260
70
60
1,09
1,36
17
OKCV 200 NTR
1287
600
907
584
255
670
240
616
362
252
OKCV 180 NTR
OKCV 200 NTR
180
200
0,6
0,4
80
60
76
80
0,75
0,75
18000
18000
38
43
11000
11000
63
72
1,39
1,4