MECHANICAL CONNECTION OF LX AIR
CONDITIONER
The air conditioner is a high-pressure system! The air conditioner has an indoor and
outdoor unit that may only be wired by a qualified person authorised to operate high-
pressure devices!
4.1 FILLING THE AIR CONDITIONER
The LX air conditioner is filled with a mixture (coolant) R 410 A.
4.2 CONNECTING THE INDOOR AND OUTDOOR UNIT
The LX air-conditioning unit is not supplied with connecting pipes between the indoor and
the outdoor unit!
This is because of almost every distance between the indoor and outdoor unit is different. If
connecting pipes with a fixed length were included in the package, and the actual distance were
longer, it would be impossible to use the supplied pipes, which would create unnecessary waste.
4.3

DIAMETERS OF CONNECTING PIPES

Dimension of pipeline
Gas
Condensate
4.4
MAXIMUM VERTICAL DISTANCE AND DISTANCE
BETWEEN THE INDOOR AND OUTDOOR UNIT
Standard pipe length
(m)
Maximum cant
B (m)
Maximum distance
A (m)
LX 35
½" – Ø 12.7 mm
¼" – Ø 6.35 mm
LX 35
LX 50
5
5
10
20
20
30
LX 50
½" – Ø 12.7 mm
¼" – Ø 6.35 mm
- 10 -