Bosch Vision 800 Series Servicehandleiding - Pagina 12
Blader online of download pdf Servicehandleiding voor {categorie_naam} Bosch Vision 800 Series. Bosch Vision 800 Series 36 pagina's. Gas slide-in ranges
Ook voor Bosch Vision 800 Series: Gebruiksaanwijzing (40 pagina's), Afmetingen en specificaties (2 pagina's), Installatiehandleiding (6 pagina's), Servicehandleiding (43 pagina's), Handleiding voor installatie-instructies (28 pagina's)
58300000194725 ARA EN B
5.2
Flame
Characteristics:
Figure 4 NG/LP flame characteristics
5.3
Spark Module
The 5-point, 120V 60Hz 2VA flame-sensing spark module has
terminal connections on the top for power and the spark switch wires
and on the bottom for the spark igniter (electrode) wires.
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
Yellow Flames: Further adjustment is
needed
Yellow Tips on Outer Cones:
Normal for LP gas
Soft Blue Flames: Normal for natural
gas
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
MAY 2016
Figure 5 Five-point spark module
5.3.1 Flame Rectification
Gas cooktop spark modules use flame rectification to reliably re-ignite
a burner if the flame goes out.
Flame rectification occurs when flame molecules ionize, allowing them
to conduct electricity. Because the cooktop frame is much larger than
the spark igniters (electrodes), the flame acts as an AC to DC rectifier.
The spark module applies an AC voltage to the spark igniter, which is
rectified from AC to DC. The spark module measures this small micro
amp (µA) DC current and senses a flame is present. If the current is
interrupted, the spark module senses the flame has gone out and re-
ignites the burner.
If burner bases aren't solidly grounded, they won't be connected to
the cooktop frame, the circuit through the cooktop frame to the spark
module won't be connected, and there will be no flame rectification
(no DC voltage sensed), so burners won't stay lit.
Service Manual for Bosch 800 Series Gas Slide-in Ranges
Spark switch and power connections
Igniter (electrode) wire connections
Page 12 of 36
800 944-2904