ATI Audio DA1000 Bedienings- en onderhoudshandleiding - Pagina 6

Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} ATI Audio DA1000. ATI Audio DA1000 7 pagina's. 1x8 analog audio distribution amplifier/ microamp series

ATI Audio DA1000 Bedienings- en onderhoudshandleiding
TECHNICAL SPECIFICATIONS
OUTPUT CLIPPING LEVEL
DISTORTION
FREQUENCY RESPONSE
OUTPUT NOISE
HUM REJECTION
INPUT IMPEDANCE
GAIN
OUTPUT ISOLATION
POWER
SIZE
WEIGHT
MOUNTING
ATI Audio Inc.
■ Tel: 856-626-3480
+24dBm @ 600 ohms load
.2% maximum THD, 20-20kHz @+24dBm
output and input levels to +24dBm
±.25dB, 20 to 20kHz; -3dB at 100 kHz
-70dBm maximum @ 20kHz measurement
bandwidth, 600 ohm source impedance and max
gain
80dB for common mode hum
Balanced differential inputs, 30,000 ohms
bridging. +24dBm maximum input level
26dB, front panel adjustable
70dB minimum at 1 kHz, any output to any other
output; unit will tolerate up to two shorted
outputs with no reduction in headroom
115VAC, 47-63 Hz
230VAC, 47-63 Hz with internal wiring change
8.5" (21.6cm) W x 1.75" (4.4cm) H x 7"
(17.8cm) D
2.5 lbs. (1.1kg) Net, 4 lbs. (1.8kg) Shipping
Suction feet for non-slip desk mounting
Rack mount system P/N 21075-501 mounts up to
two units in one rack
1/2RU Filler Panel P/N 21098-501
Fax: 856-504-0220
www.
audio.com