Chapter 2 Operation
2.1 Front Panel
2.1.1 Indicators
There are seven indicators in the front panel of FE1/V.35 interface converter,
from right to left:
PWR
E1LOS
E1LOF
TXD
RXD
PTOK
TEST/
CRC_ERR
User Manual
Fig 1. Front panel of FE1/V.35 Interface Converter
Indicator of power supply
Green
Bright when power is on
Alarm indicator of E1 code-breaking
Bright when local device E1 code-breaking
Red
Blinking when remote device E1 code-breaking
Local has higher priority
Alarm indicator of E1 frame-lost
Bright when local device E1 frame lost
Red
Blinking when remote device E1 frame lost.
Local has higher priority
Indicator of V.35 data transmittal
Green
Blinking when V.35 data transmitted
Indicator of V.35 data receiving
Green
Blinking when V.35 data received
Indicator of test result
Green
OFF when device work normally
Bright when the test result is right
Indicator of test and CRC error
OFF when device work normally
Double
Red: bright when local CRC error
colors
Blinking when remote CRC error
Green: bright when device in test mode
Blinking when remote device in test mode
Table 1. Specification of front panel indicators
5-20