SYSTEM SET-UP & CHECKOUT
Skip set up and proceed to INSTALLER TEST MODE on page 10 unless:
• A Model A77 or other external control is to be installed
• changing the air sampling rate
1. Make sure the wire access cover has been snapped back onto the
on-board control .
2. Plug unit in and turn power switch to ON .
3. The on-board control screen should display OFF .
90-1854
NOTE: If the display backlight is not on, the first button press (any
button) will only turn on the backlight . Press the button a second time
to achieve function .
4. Hold the MODE button on the on-board control for 3 seconds to
enter the Installer Set-up Menu .
5. Navigate through the following screens to set up the dehumidifier
for the installed application .
Use the UP or DOWN buttons to select items and use MODE to
switch to the next set-up option . To exit installer set-up, all options
must be scrolled through using the MODE button .
6. After the installer set up options have been completed, DONE will
blink for 3 seconds and the control will return to the OFF screen .
90-1854
REMOTE CONTROL
EXTERNAL CONTROL
90-1854
If not installing an A77, leave
DISABLED and press MODE to go
to the next screen . .
90-1854
If installing an A77, use the UP or
DOWN button to select ENABLED,
then press MODE to go to the next
screen .
90-1854
If using the dehumidifier on-board
control, leave DISABLED and press
MODE to go to the next screen .
90-1854
If using a Model 8800 series
thermostat or alternate control as
an external control, use the UP or
DOWN button to select ENABLED,
then press MODE to go to the next
screen .
90-1854
9