7
Look-down and walk test
7.1
Look-down zone
The detector has a manual cam to enable or disable the look-down zone. Enable the look-
down zone to detect motion under the detector area.
To reduce false alarms, disable the look-down lens for locations where small animals are likely
to cross the look-down zone.
Turn left to disable the look-down zone. Turn right to enable the look-down zone.
7.2
Walk test LED
The walk test LED indicates the detector's operational status.
2 min
Bosch Building Technologies
During the warm-up period (after providing power to the
device), the LED flashes continuously until the device is
ready for use.
During walk test, the LED indicates PIR and microwave
activity activity and also a motion alarm condition (dual
alarm).
If the detector is in a self test fault condition, the LED
flashes 4 times repeatedly.