RETURNING TO FACTORY
DEFAULT SETTINGS:
LOCKING THE BUTTON
PANEL:
SYNC-ON-GREEN, PEDESTAL ON/OFF,
PAL M AND PAL N:
LOCKING THE GENLOCK AND
GENLOCK PHASING BUTTONS:
Page 8
Reset: You may quickly return all Scan Do Pro II functions to their
factory default settings by simultaneously pressing the Test and ←
buttons.
Lock/Unlock: The button panel may be locked or unlocked by simulta-
neously pressing the following button combinations:
An internal switch located on the Scan Do Pro II and Pro II/D board
allows you to configure the unit for several custom settings. To access the
switch, first disconnect AC power. Then, remove the two screws from the
front panel. Drop the panel, which is connected to the board by a ribbon
cable. The switch, labeled "S2", is blue with four white levers and is located
on the front left corner of the board. The unit comes preset with all levers
set to "OFF." Printed to the left of the switch, on the board, are instructions
for use. A summary is provided below:
Sync-on-Green:
Pedestal On/Off: Unit is preset for Pedestal Use. To turn it off, set
PAL M:
PAL N:
Genlock Buttons Lock/Unlock: Once the genlock timing has been set,
it may be desireable to lock the Genlock and the Genlock Phasing
buttons so that nothing happens if they are accidentally pressed.This can
be accomplished by simultaneously pressing the following button combi-
nations:
GENLOCK BUTTON LOCK:
GENLOCK BUTTON UNLOCK: VERT FILTER AND ↓ ↓ ↓ ↓ ↓
When the genlock keys are locked, the function of the arrow keys will
automatically become set to the panning mode. Once the genlock keys are
unlocked, the Genlock Phasing button must be pressed to put the arrow
keys back in genlock phasing mode.
Scan Do Pro II User's Manual
TEST AND ↑ ↑ ↑ ↑ ↑
LOCK:
TEST AND ↓ ↓ ↓ ↓ ↓
UNLOCK:
Set "lever 1" to "ON"
the switch to "ON"
Set "lever 3" to "ON" and set exterior back panel
switch to NTSC.
Set "lever 4" to "ON" and set exterior back panel
switch to PAL.
VERT FILTER AND ↑ ↑ ↑ ↑ ↑