Communications Specialties FIBERLINK XRD-8050 Gebruikershandleiding - Pagina 15
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} Communications Specialties FIBERLINK XRD-8050. Communications Specialties FIBERLINK XRD-8050 17 pagina's. Fiber optic linear multidrop rs-232 transmission system for traffic signal controller pplications
B. Check Optical Connectors
1.
Is the correct connector being used for the type of fiber optic cable
employed? Some multimode connectors look the same as their single-
mode counterparts at first glance.
2.
Are the ends of the connectors free from all dust or dirt? If not, gently
clean the ends with a clean cloth moistened with alcohol.
3.
Is the fiber broken in the connector? A quick inspection with an
inexpensive 10X jeweler's loop can determine this.
4.
Is the fiber protruding from the tip of the optical connector? If so,
refinishing will be necessary.
C. Check Fiber Optic Cable
1.
Is the correct fiber size being used with the correct
transmitter/receiver combination?
2.
Does the fiber optic cable have too much attenuation (loss) for the
system?
3.
Does the fiber optic cable pass light at all? A small penlight type
flashlight can usually be used for this test.
4.
Is the fiber optic cable pulled too tightly around a sharp corner?
D. Check Receiver (or receiving section of a transceiver)
1.
Is the operating power (DC, AC, Voltages) correct?
2.
Are the pins being used on the connector or terminal block correct?
3.
Is light coming out of the fiber optic cable? This may be difficult to
see in many cases, but sometimes a very dim glow is present. Note
that you can only see 850nm light. Light at 1300nm is invisible.
4.
Is the optical connector on the receiver clear of any obstruction or
minute dirt particles?
5.
Does the fact that signal ground, power ground and the housing are
common cause a short-circuit anywhere in the system?
14