However, it is not necessary to purge when the temperature is higher than 750°C. Oxygen pipe
or gas pipe connected with burner should be tight enough with no leakage, also the periodically
check air or fuel nozzles of the burners to prevent to be blocked by dust, slag or other materials.
ATTENTION:DANGER OF BEEN BURNT
When burner in operation, combustion is severe, so the burner must be fixed. Hoses or cables in
area of the combustion system must be suitable for high temperature, to prevent high
temperature failure or cause safety accidents. Burners should be periodically inspected and
cleaned. Copper wire brush may be used, if necessary, to clean burner head. The burner system
should be checked twice a year for safety operation.
4. Description
FFO – FlexFire® oxygen burner is a trademark of Anderson Thermal Solutions (Suzhou) Co., Ltd.,
it is designed for oxygen firing glass furnace.
FFO52 - Oxygen FlexFire® burner with wide flat flame coverage and high flame brightness; It is
one of the ideal burners for glass melting.
–
When the burner stops for more than 20 minutes, remove the burner
and seal the burner block opening. Prevent burner damage.
–
To adjust the burner, loosen fixing T-bolts and lock it again after the
adjustment is completed
–
Do not remove the metal gas hose or locking device when the gas is not
completely shut down
Anderson Thermal Soluions(Suzhou)Co., Ltd
Anderson Thermal Solutions – FFO52 Burner Operation Manual
Figure 1: FlexFire®52 Oxygen Burner
Attention!
3