Anderson LN Beknopte installatiehandleiding
Blader online of download pdf Beknopte installatiehandleiding voor {categorie_naam} Anderson LN. Anderson LN 2 pagina's. Ln potentiometric level transmitter
Anderson Instrument Co., Inc.
156 Auriesville Road
Fultonville, NY 12072
Phone: 518-922-5315 or 800-833-0081
www.anderson-negele.com
1. Insert cable through Pressing Screw, Compression
Ring, Seal Grommet, and Sleeve as shown below.
2. Strip back 1-1/4" of outer sheathing, cut off any excess
wires, shield and ground. Strip off 1/4" insulation from
remaining four wires. It is not necessary or recommended
Shown With
Cap Removed
CABLE REQUIREMENTS
4 conductor, stranded, 18-24 AWG,
shielded with ground.
4-8mm (0.16-0.31") Cable Sheath
OD.
To install connector, simply line up key, press
into receptacle, and hand-tighten the
*Receptacle pins should be coated with
USDA approved dielectric grease to
Minimize possibility of corrosion.
Rev. 2.1
Section 1 - Field Wireable Connector
3. Orient Connector end so that
center pin connecting screw is
horizontal facing right (see
detail).
Retaining Ring
Connector End
Pin 2 - Black
(-PWR)
Pin 3 - Green
(LOOP- Return)
DETAIL
*Dielectric Grease
P/N: 5662400000
Doc 1136
Technical Bulletin
LN Potentiometric Level Transmitter
Quick Start Installation Guide
4. Wire PWR + (red) wire to top-right
terminal, and PWR - (black) wire to
top-left terminal. Wire LOOP + (white) to
center terminal and LOOP - (green) to
bottom left terminal.
5. Screw on the Sleeve. Hand-tighten only.
Sleeve
Compression
Ring
Seal
-2 included choose one to accommodate cable OD
Grommet
6. Press the Seal Grommet into the Sleeve and
Pin 1 - Red
hand-tighten the Pressing Screw against the
(+PWR 18-36 VDC)
compression ring.
Pin 5 - White
7. Use a wrench to tighten the Pressing Screw
(LOOP+)
another 3/4 turn. Do not over-tighten!
Field Wireable Connector
P/N: 42119B0000 (without cable)
Molded Cord Set - Heavy Duty
P/N: 42117F0025
42117F0050
42117F0100
Molded Cord Set
P/N: 42117K0025
42117K0050
42117K0100
Pressing Screw
Loop+ (white) wire
Loop- return (green) wire
+PWR (red) wire
-PWR (black) wire
Shield (clear or bare) wire
PWR+ (brown) wire
PWR- (white) wire
Loop + (grey) wire
Loop - (blue) wire
Shield (clear or bare) wire
Loop+ (white) wire
Loop- return (green) wire
+PWR (red) wire
-PWR (black) wire
Shield (clear or bare) wire
Note: Green and White not used
on 2 wire devices.
Shield not connected to nut.