Bosch WTA3500 Gebruiks- en onderhoudshandleiding - Pagina 9

Blader online of download pdf Gebruiks- en onderhoudshandleiding voor {categorie_naam} Bosch WTA3500. Bosch WTA3500 12 pagina's. Electric vented dryer and electric condensation dryer
Ook voor Bosch WTA3500: Gebruiks- en onderhoudshandleiding (13 pagina's), Handleiding voor installatie-instructies (12 pagina's), Gebruiksaanwijzing (44 pagina's)

Bosch WTA3500 Gebruiks- en onderhoudshandleiding
CARE and CLEANING
The housing and control panel should only be
cleaned with a soft cloth rinsed in soapy water, or
with a solvent free, non-scouring cleaning agent.
Other areas requiring periodic leaning or
maintenance are listed below:
Lint Filter
The lint filter should be cleaned after each use, If the
"Lint Filter" light becomes illuminated and the buzzer
sounds during operation of the dryer:
1. Immediately stop the dryer by depressing the
"ON/OFF" button.
2. Depress the "DOOR" button and open the door.
3. Remove the filter.
4. Clean the filter.
5. Replace the filter.
6. Let the dryer cool down.
7. Close the door.
8. Press the "START" button to restart the dryer.
Heat Exchanger (WTL models only)
The heat exchanger should be cleaned 3-4 times a
year; more often if used frequently. To clean the heat
exchanger:
1. With the dryer turned off and disconnected from
the electrical supply. Disconnect the power cord by
grasping the plug, not the cord.
2. Depress the "DOOR" button and open the door.
3. Press the button for opening the heat
exchanger/inlet panel, as shown in Figure 6.
Figure 6
4. Open the panel fully.
5. Turn the retainers on each side of the heat
exchanger towards each other, in the direction of
the arrows as shown in Figure 7.
6. Remove the heat exchanger by slowly pulling it
forward and out of the dryer.
7. Clean the heat exchanger thoroughly with water.
Allow the water to run freely through the heat
exchanger. See Figure 8.
Figure 7.
Figure 8.
8.
Allow heat exchanger to dry thoroughly before
reinserting into the dryer.
9.
Once the heat exchanger is completely dry,
reinsert it into the dryer. The handle must be
underneath the heat exchanger. Turn the
retainers back to their original position.
10. Close the heat exchanger/inlet panel by pressing
firmly on both the upper left and right hand sides,
as shown in Figure 9, until it snaps into place.
Note: The dryer door will only be able to be closed if
the heat exchanger/inlet panel is properly
closed and locked in place.
Figure 9.
9