PLUMBERS INSTALLATION INSTRUCTIONS
Important Information
* HOT & COLD WATER INLET PRESSURES MUST BE EQUAL.
Not suitable for gravity feed systems.
*
* Basin outlet is fitted with a flow regulated aerator insert.
This low flow rate may not be suitable for connection to
some Instantaneous Gas Water Heaters, some Tempering
Valves, some Solar Water Heaters & some Thermostatic
Mixing Valves.
Check with the manufacturers of these products.
Note:- An aerator insert kit (Part No. SP2001), is available
if required. For applications where flow regulation is not
suitable (e.g. bath) a full flow aerator insert has been
provided within the packaging. To convert the basin
outlet to a bath outlet, refer to 'Replacing Aerator Insert'
Brazed connections should NOT be made directly onto the
*
mixer, as excessive heat will cause permanent damage.
*
All pipework must be thoroughly flushed prior to installation,
as foreign materials may block the flow regulating device
and reduce the flow of water.
Installation
1) Determine if outlet (17) is to be positioned to the right or the left of
the mixer body (8) when installed (Fig 3.). Fit suitable fittings to the
connection ports of the mixer (8) (Fig 2.). When facing the mixer,
the connections should be as follows :
Hot water inlet connection 'H' to the left.
Cold water inlet connection 'C' to the right.
Mixed water outlet connection, vertically upwards.
+
Note: A suitable elbow fitting (13
) should be fitted to the
inlet connection adjacent to the lugged elbow (12) (Fig.2).
Attach the mixer body (8) & the lugged elbow (12) to the mounting
plate (11) with screws (10) and tighten using a suitable screw driver.
Note: Mounting plate can be rotated 180 to change hand.
2)
Fit the mounting plate (11) onto a suitable noggin in the wall &
secure using screws through the holes in each corner.
Important :
The mounting plate (11) must be installed horizontal & parallel
*
to the face of the wall studs to ensure correct installation.
To avoid damaging the decorative finish, do not remove the
*
protective sleeve until installation has been completed.
3)
Complete the connections. (Fig. 2). Check all connections for
leaks and the mixer for correct operation.
Note: Pipework and fittings are not supplied.
AURA - WALL BASIN/BATH MIXER
WATER EFFICIENT TAPWARE
Pressure & Temperature Requirements.
Hot and cold water inlet pressures should be equal.
Static inlet pressure range : 150-1000 kPa
New Regulation:- 500 kPa maximum static pressure
at any outlet within a building. (Ref. AS/NZS 3500.1)
Maximum hot water temperature : 80 C.
Installation Requirements.
The installing plumber is responsible for waterproofing
all penetrations for Taps in Shower areas at installation
by a proprietary flange system or a sealant.(Ref AS3740)
4) Apply a suitable clear sealant to the back face of the cover
plate (9), leaving an unsealed section at the bottom for drainage.
Carefully fit the cover plate (9) onto the mixer body (8), push
firmly on the cover plate (9) until it contacts the wall/tile face.
Wipe clean any excess sealant from the chrome surfaces & the
wall/tile face (See Fig. 1). Check that the thread on the lugged
elbow (12) is the correct length, as shown (Fig. 4). Cut to length
if required ensuring end face is square. Apply thread tape to the
thread. Important: Care must be taken that thread tape cannot
become dislodged and block the flow regulating device, causing
a reduction in water flow. To ensure correct installation, length
of exposed thread must not exceed 10mm.
5)
Fit handle (1) taking care that it is pushed fully onto cartridge
stem, tighten screw (4) using the 2.5mm allen key (3) then fit
plug (2).
6) Screw the spigot (15) onto the thread of the lugged elbow (12)
using a 10mm allen key (14
securely against the wall/tile face. DO NOT OVERTIGHTEN.
Apply suitable lubricant to 'O'Rings on spigot (15).
7) Fit wall outlet (17) onto the spigot (15), then carefully push it
firmly against the cover plate while tightening grub screws (16)
using the 2.5mm allen key (3) provided. Take care that the
aerator housing (20) is pointing vertically downwards before
tightening screws (16). (Fig.4)
8)
Turn on Hot and Cold water supplies and check operation.
IMPORTANT
+
) untill the cover plate (9) is held
+ Not supplied.
Replacing Cartridge (Fig. 1)
1)
Turn off hot and cold water supplies.
2)
Carefully remove plug (2) before using a 2.5mm allen key (3) to
loosen grub screw (4) and remove handle (1). Remove cap (5)
taking care not to damage the decorative finish. Unscrew nut (6)
then lift out old cartridge (7).
3)
Ensure inside face of mixer body (8) is clean. Check that seal is in
position in base of new cartridge (7). Fit new cartridge (7) into
mixer body (8), taking care that two lugs on base of cartridge (7)
fit into mating holes in mixer body (8).
4)
Screw on nut (6). Important:- Nut (6) should be tightened to a
torque of 10 Nm.
5)
Fit handle (1) taking care that it is pushed fully onto cartridge
stem, then tighten grub screw (4) using the 2.5mm allen key (3).
Replace plug (2), taking care not to damage the decorative finish.
6) Turn on water supplies and check operation.
Replacing Aerator Insert(Fig.4)
1) Carefully remove aerator housing (20) from outlet (17),
taking care not to damage the decorative finish.
2) Remove 'O'Ring (18) & aerator insert (19) from aerator housing
(20). Check that aerator housing (20) is clean. Deposits of lime
can be removed by washing in a vinegar solution.
3) Fit new aerator insert (19) into aerator housing (20) followed
by 'O'Ring (18) then screw assembly into outlet (17) and
tighten securely (to prevent removal by hand).
(SHEET 1 OF 2)
IS1637A(01/17)