Caroma G Series Plus Installatie-instructies

Blader online of download pdf Installatie-instructies voor {categorie_naam} Caroma G Series Plus. Caroma G Series Plus 2 pagina's. Wall sink exposed set water efficient tapware

'G' SERIES PLUS- WALL SINK EXPOSED SET
R
PLUMBERS INSTALLATION INSTRUCTIONS
Important Information
Not suitable for gravity feed systems.
*
It is recommended that the outlet (19) be fitted prior to
*
installing the breech (11). (see Fig.5, Sht 2).
*
The outlet is fitted with a flow regulated aerator insert.
* All pipework must be thoroughly flushed prior to
installation, as foreign materials may block the flow
regulating device and reduce the flow of water.
Note: Aerator insert housing must be retightened to
prevent removal by hand.
G1/2B inlet nipples (16) must be square to wall/tile face
*
and mounted accurately with the correct distance
apart (Fig.1) to ensure a satisfactory installation.
Installation (Fig.1, 2 & 3 or 4)
1)
Check that threaded nipples (16) are the correct length,
as shown (Fig.2). Cut to length if required ensuring end
face is square. Apply thread sealant or tape to the thread.
Important: Care must be taken that thread tape cannot
become dislodged and block the flow regulated device,
causing a reduction in water flow.
2)
Screw connector (15) onto each inlet nipple (16) using a
10mm allen key (not supplied). Each connector (15)
should be tightened equally until the correct centre
distance (Fig.1) is acheived & the breech (11) is
horizontal. Use the breech (11) to check for correct
installation & adjust the connectors (15) accordingly.
3) Apply suitable lubricant to the 'O'Rings on the spigot of
connectors (15). Fit the adaptors (12) of the breech (11)
equally onto the spigots of connectors (15) until they
contact the connector front face then tighten screws (13)
using a 2.5mm allen key.
4) Determine handle closing position.
Forward closing lever handles (ideal for opening using
elbows) (Fig.3). Proceed to step 6.
Outward closing lever handles (more suitable for
opening by hand) (Fig.4). Proceed to step 5.
5)
Remove locknuts (7) and fibre washers from
cartridges (8). Unscrew cartridges (8) from breech
bodies (10). Screw cartridge (8) (with red seal 9)
into left hand 'hot side' breech body (10). Using a
suitable spanner, tighten cartridge (8) until it
comes to a firm stop (DO NOT TIGHTEN
CARTRIDGE USING SPINDLE). Fit fibre washer &
then locknut (7) and tighten using a suitable
spanner, taking care not to damage the thread.
Fit cartridge (8) (with blue seal 9) into right hand
'cold side' breech body (10) in a similar manner.
WATER EFFICIENT TAPWARE
IMPORTANT
Pressure & Temperature Requirements.
Hot and cold water inlet pressures should be equal.
Static inlet pressure range : 150 -1000 kPa
New Regulation :-500 kPa maximum static pressure
at any outlet within a building.(Ref. AS/NZS 3500.1)
Maximum hot water temperature : 80 C.
Deck Requirements
Centre distance between inlet nipples :200 9mm
6)
With cartridge spindles in the fully closed position (Fig.3 or 4), fit inserts (6) onto spindles then
check that lever of handles (1) are in correct alignment with each other when fitted to handle
inserts (6). For small adjustments to handle position, cartridge (8) can be rotated slightly in an
anti-clockwise direction until handles are aligned before tightening locknut (7). Remove handles
(1) then fit washers (5) & nuts (4) to thread of spindles and tighten to secure inserts (6). Align
handles (1) as before then engage with insert (6) & tighten screw (2) with 2mm allen key (3).
Hot Handle
Fully
Closed
Fully Open
12
Wall/tile face
'O'Rings
Spigot
16
15
1 2 m m
Fig.2 Side View
Hot Handle
Fully
Open
Fully Closed
Cold Handle
Fully
closed
Fig.4
Fully Open
11
13
14
Fig.1 Front View
Fig.3
Fully Closed
3
2
Spindle
2 0 0 m m
(SHEET 1 OF 2)
IS1592B(04/17)
Cold Handle
Fully
Open
1
4
5
6
7
Fibre Washer
8
9
10