With respect to national rules - however at least every year - the following must be checked for by a qualified expert: operating
functions, damage, abnormal wear, the saddle for incipient fractures, pressure relief valve's adjustment, cylinder and pump for
leaks. Wear or breakage on wheels. And also that labels of safety-related significance are readable.
If anomalies appear, the jack must not be used
Troubleshooting:
1. The jack cannot lift completely up to the top even though the pump is running: Fill up the oil, see the oil quantity!
2. The air motor is running slowly or halts: The air pressure from outside is not sufficient, check the air supply!
3. The load is dropping: check for leaks. Introduce press ball with mandrel (only authorized personnel).
4. Oil spills from cylinder: Replace cylinder gaskets. Sudden oil spills from air motor and handle may be due to incorrect handling,
for example if the jack has been laying on its side. If so, the oil spill (from the oil tank) will stop when the jack is standing on its
wheels again - but the oil will continue to drip for some hours.
Spare parts:
Always replace worn or defective parts with original spare parts.
Destruction:
When the jack is to be disposed of after many years of use, the oil must be drained out and disposed of in a lawful manner.