Introduction
Thank you for purchasing Atlantic's Typhoon TA1800/TA3600 Air Pump. Before using this air
pump please take a moment to review this manual.
This pump is designed to pump air. The oil-free, double damping air pump system
produces a large volume of air with little noise. The aluminum casing and outer housing
cover dissipate heat quickly and shield the compressor from the elements in an outdoor
application.
Atlantic's Typhoon Air Pump may be used in a variety of water-related applications
including oxygenation of ponds and aquariums and de-icing of outdoor ponds.
To avoid an accident, do not use the pump in any way other than as described in this
manual. Please note the manufacturer cannot be responsible for accidents arising because
the product was not used as prescribed. After reading this manual keep it as a reference in
case questions arise during use.
MODEL
TA1800
⅜" insert, ½" slip
TA3600
⅜" insert, ⅝" slip
MODEL
LPM /
TA1800
CFM
LPM /
TA3600
CFM
Prior to Operation and Installation
When the pump is delivered, first perform the following checks:
• Check for any damage to pump and power cable that may have occurred during shipping.
• Check the model number to make sure it is the product that was ordered and verify the
voltage and frequency are correct.
Caution
• DO NOT operate this product under any condition other than those for which it is specified.
Failure to observe this precaution can lead to electrical shock, electrical leakage, fire, water
leakage or other problems.
• Please only use with a power supply voltage within 110-120 volt 60 Hz.
• Always turn off power or unplug the pump prior to performing any maintenance or placing
your hands into the water.
• CAUTION:
THIS AIR PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND FAULT
CIRCUIT INTERRUPTER.
• WARNING:
RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND
GROUNDING-TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN
THAT IT IS CONNECTED ONLY TO A PROPERLY GROUNDED, GROUNDING TYPE RECEPTACLE.
2
OUTLET
VOLTS
115
115
AIR PUMP OUTPUT
MAX
@ 1'
@ 2'
30 /
25 /
1.06
0.88
0.74
60 /
54 /
47 /
2.12
1.91
1.66
WATTS
PRESSURE
25
35
@ 3'
@ 4'
21 /
17 /
13 /
0.60
0.46
40 /
34 /
1.41
1.2
MAX
MAX
DEPTH
3 psi
7'
5 psi
11'
@ 5'
@6'
9 /
4 /
0.32
0.14
28 /
23 /
0.99
0.81
CORD
LENGTH
6'
6'
@8'
@10'
---
---
12 /
2 /
0.42
0.07