Dri-Air Industries ARID-X Bedieningshandleiding - Pagina 9
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} Dri-Air Industries ARID-X. Dri-Air Industries ARID-X 20 pagina's. Floor mount dryers
Ook voor Dri-Air Industries ARID-X: Bedieningshandleiding (19 pagina's)
PLC STANDARD
ELECTRICS
OPERATING MANUAL - ARID-X, HP4-X 18-100 FM DRYERS
Revision 10/8/02
DRI-AIR
The control package includes a PLC controller which is
programmed for the drying cycle previously discussed. The
display board indicates the machine status, heater operation
and alarms. See section on start up for details.
Below are descriptions of the inputs and outputs of the PLC
which are used for trouble shooting. A lit LED indicates the
input or output is actuated. All inputs are 12 volts AC and all
outputs are 110 volts AC and 15 v DC to the heater relays.
Refer to the electrical schematic for more detail.
1
1
U 2A
D 11
D 8
D 13
D 9
D 14
D 10
U 9
C 13
C 15
U 5
U 2
D 12
R 11
R 12
D 15
R 13
R 14
S2
S1
D 16
J12
J5
C 11
DRI-AIR INDUSTRIES
EXPANDER BD
REV C
INDUSTRIES, INC.
J118
J2
C 14
D 20
C 20
U 7
XX
PO WER
U N U SED
U N U SED
H I TEM P
M AIN
SAFETY
TEM P
50-300
N O N H .P.
Page 9