Electrical connection
Check that the installation complies with standards of local
building, gas and electrical authorities. Before connecting to
the mains supply ensure that the mains voltage corresponds
to the voltage on the rating plate inside the cooker hood.
Safety warnings – For the installer
When installing the cooker hood, make sure you adhere to
the minimum and maximum distances from the cooker hood
base to the hob surface (as per table on right hand side).
Exhaust duct installation: The following rules must be
strictly followed to obtain optimal air extraction.
• Keep exhaust duct short and straight
• Do not reduce the size or restrict exhaust duct.
• Keep bends in the exhaust duct to a minimum.
• When using flexible duct always install duct with helix
pulled taut to minimise pressure loss.
• Failure to observe these basic instructions will drastically
reduce the performance and increase the noise levels of
the cooker hood.
Exhaust air must not be discharged into a wall cavity, unless
the cavity is designed for that purpose.
The exhaust from the cooker hood must not be discharged
into any heating flue, which may carry combustion products
from other sources
NOTE: Some installations may require the telescopic
exhaust cover to be cut to length. Cut with sharp tin snips
or a fine-tooth hack saw blade, taking care not to distort or
dent the exhaust cover.
Rangehood installation
(rear to wall)
ceiling
(rear to wall)
mounted
bracket
ceiling
mounted
bracket
46mm
46mm
(rear view of hood)
(rear view of hood)
71mm
324mm
349mm
374mm
71mm
399mm
324mm
349mm
374mm
399mm
344mm
344mm
303mm
37mm
303mm
155mm
155mm
37mm
155mm
155mm
ceiling
ceiling
168mm
168mm
168mm
168mm
wall mounting
brackets
wall mounting
brackets
Installation sequence
1. Using a spirit level mark a vertical centre line on the wall
where the hood is to be positioned, and a horizontal line
at the hood base position (refer diagram bottom left).
NOTE: The height of the underside of the hood body must
be a minimum of 600mm above an electric cooktop &
650mm above a gas cook top and a maximum height of
800mm (refer to table below).
Distance from hood base to top of hob
hob type
gas
electric
* If the instructions of the hob specify a greater distance than the
minimum above, then that shall be the minimum height for installation
2. Mark the location for the wall and ceiling bracket fixing
points above the hood base using the hood base as the
reference point (refer diagram bottom left).
3. Install wall and ceiling mounting brackets with suitable
screws (to support a total weight of 30kg) to the wall at the
positions marked in diagram bottom left.
4. Remove the protective plastic film from the hood body
and hang hood on the mounting brackets then secure at
the anti-tilt locations as indicated in diagram bottom left.
Depending on the preferred installation/ducting mode,
follow step 5a or 5b below.
5a. Recirculating mode (Fig. a). Using the centre line,
secure the ceiling mount bracket to the wall using
suitable screws. Attach the recirculating T-piece
(optional kit AR600RK) to the ceiling mount bracket.
Install flexible pipe between T-piece and fan transition
outlet. Use cable ties or suitable duct tape to secure
flexible pipe to T-piece.
NOTE: When installed in recirculation mode, it is
recommended to use a carbon filter (included in
recirculation kit AR600K) to prevent odours being
emitted back into the room.
OR
5b. Ducted mode (Fig. b). The canopy rangehood has been
supplied with flexible exhaust pipe and duct transition
piece, alternatively a 150mm dia. non-combustible flue
pipe can be used. Continue the centre line to the ceiling.
Attach the ceiling mount bracket on the centre line. Fit
preferred flue pipe to the fan transition duct.
anti-tilt fixing points
(a)
anti-tilt fixing points
hood
base
hood
base
top
of hob
top
of hob
electrolux e:line rangehood installation 3
minimum*
650mm
600mm
(b)
maximum
800mm
800mm