out-going airstream, somewhat constricted by its
passage through the drip tray, is measured at 244
CFM with ducting.

Automatic Defrost

Extremely low outdoor temperatures may
freeze water that has condensed in the Core. A
probe is inserted into the Core. If it senses a
freezing temperature it switches off the blower
pulling air from the outdoors. During the shut-off
period the other blower continues to run, forcing
COPYRIGHT _ DRI-EAZ PRODUCTS, INC. 1997
room temperature air through the Core and melt-
ing the ice. The first blower will restart after the
temperature in the Core rises to 35°F (1°C).
Before shutting off the Dri-X, remove ducting
from the vent marked "Fresh Air from Outdoors."
Then let the unit run 10 more minutes, to pump
away any condensation and prevent leakage.
8