Electrolux SL series Gebruik - Pagina 33
Blader online of download pdf Gebruik voor {categorie_naam} Electrolux SL series. Electrolux SL series 45 pagina's.
COOKER HOOD
GENERAL
The model you have selected is a decorative suction cooker hood which can also work as
filtering hood.
A SUCTION HOOD extracts air, fumes and vapours from the inside environment and then
expels them outside. It is not necessary to use carbon filters for purifying.
A FILTERING HOOD extracts air, fumes and vapours from the inside environment, purifies
them by means of carbon filters and then emits the purified air into the same environment. In
this case, the use of carbon filters is absolutely necessary .
Carbon filters are available separately and can be purchased as optional accessories (see
OPTIONAL ACCESSORIES).
BEFORE MOUNTING
Before mounting you should:
Check that the minimum distances between the lower part of the cooker hood and the upper
part of the cooker as given in FIGURES M 1. We advice a distance between 700 and 800 mm.
WARNING! If the user decides to install the hood at lower distances, the manufacturer
declines any responsibility for eventual damages caused by the hood due to strong heat
or damages to property or persons etc. caused directly or indirectly by any type of
malfunctioning breakdown or possible fire.
Arrange for a socket outlet or standard connection to the electric mains.
If the hood is used as a suction hood, it is necessary to make a hole towards the outside (i.e.
in the open air) for the scavenging of the fumes.
WARNING! The air discharge of the hood must go outside by means of a separate
chimney and cannot be connected to a boiler chimney, gas, fume or vapour
scavenging pipes or any other duct. The incorrect mounting of a cooker hoods can
create fires. It is necessary to observe the cantonal dispositions of the fire-brigade.
If the hood is used as a suction hood, it is necessary to guarantee enough air- exchange .
In case a cooker hood is used in modern air tight buildings with or without confort air, it is
necessary to make in advance a planning for the air flow.
The contemporary use without danger of appliances connected to chimneys (for instance
fireplaces or furnaces, gas or other fuel stoves) and cooker hood is allowed only if the room or
the flat dispose of an opening for the air from the outside of ca 500/600 cm
of the hood a depression is avoided.
The depression in the room must not be above 4 Pa (0.04 mbar).
If the hood is to be used as a filtering hood, it is necessary to purchase carbon filters . They
are available as ACCESSORIES.
2
and if with the use
33