Atlas Copco 180PS Veiligheids- en bedieningshandleiding - Pagina 16
Blader online of download pdf Veiligheids- en bedieningshandleiding voor {categorie_naam} Atlas Copco 180PS. Atlas Copco 180PS 19 pagina's. Handheld pneumatic breakers
TEX 140PS, 150PE, 180PS, 190PE, 220PS, 230PE,
270PS, 280PE
Periodic maintenance
After each operating period of approximately 150
impact hours or twice a year the machine must be
dismantled and all parts be cleaned and checked.
This work must be performed by authorised staff,
trained for this task.
Tightening torques
NOTICE When fitting a connector to the swivel nut,
Loctite® 263™ or similar has to be used.
C
B
Screw plug, 200 Nm
A.
B.
Swivel nut, 200 Nm, use Loctite® 263™
(Loctite is a registered trademark of Henkel
Corporation. 263 is a trademark of Henkel
Corporation.)
Screw, 47 Nm
C.
Troubleshooting
If the pneumatic machine does not start, has low
power or uneven performance, check the following
points.
Check that the insertion tool being used has the
♦
correct shank dimension.
Check that the pneumatic machine is getting the
♦
correct amount of lubricant. Too much lubrication
can cause starting problems, low power or uneven
performance.
Check that the compressed air system supplies
♦
the machine with sufficient air pressure to give full
power.
Check that the dimension and length of the air
♦
hose are according to the recommendations. See
"Installation".
If there is a risk of freezing, check that the
♦
machine's exhaust ports are not blocked.
© 2012 Atlas Copco Construction Tools AB | No. 9800 0683 82f | 2012-08-07
♦
Storage
Disposal
A used machine must be treated and disposed of in
A
such a way that the greatest possible portion of the
material can be recycled and any negative influence
on the environment is kept as low as possible, and
in respect to local restrictions.
Safety and operating instructions
If the machine function is still not satisfactory after
this procedure, contact an authorised service
workshop.
Clean the machine properly before storage, in
order to avoid hazardous substances. See "Dust
and fume hazard"
Pour approximately
⁄
oz (5 cl) of oil directly into
1
2
the air inlet nipple, connect the machine to the
compressed air supply and start it for a few
seconds.
Always store the machine in a dry place.
19