Atlas Copco 8436626051 Product Instructies - Pagina 11

Blader online of download pdf Product Instructies voor {categorie_naam} Atlas Copco 8436626051. Atlas Copco 8436626051 16 pagina's. Electric straight nutrunner

Atlas Copco 8436626051 Product Instructies
ETD STR61-50-13-T25

Service

Preventing ESD problems

The components inside the tool and controller are sensitive to electrostatic discharge. To avoid future mal-
function, make sure that service and maintenance is carried out in an ESD approved work environment.
The figure below shows an example of an appropriate service work station.

Maintenance instructions

Overhaul

Service must only be carried out by qualified personnel who have access to the Service instruction and/or
have been trained for service on Tensor tools.
The electric motor is a sealed unit and may under no circumstances be opened by anyone else than
Atlas Copco Industrial Technique AB!
If you decide that the electric motor is defect or in need of service, return the complete motor unit to Atlas
Copco Industrial Technique for replacement.
Motors which have been opened by anyone else than Atlas Copco Industrial Technique will not be ser-
viced.
Overhaul and preventive maintenance is recommended at regular intervals once per year or after maxi-
mum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed if the
machine is used in heavy-duty operations. If the machine not is working properly, it should immediately be
taken away for inspection.
When dismantling the tool always use the specially designed service tool 4080 0848 80, (two service
tools are required).

Service recommendations

Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guidelines:
Clean appropriate parts accurately
Replace any defective or worn parts

Service instructions

Overhaul and preventive maintenance is recommended at regular intervals once per year or after maxi-
mum 250.000 tightening depending on which occurs sooner. More frequent overhaul may be needed if
used at high torque, high cycle rate or long tightening times. If the machine is not working properly, it
should immediately be taken away for inspection.
At the overhauls, all parts should be cleaned accurately and defective or worn parts (i.e. O-rings) should
be replaced.
EN
© Atlas Copco Industrial Technique AB - 9839 1392 01
Service
11