Atlas Copco PH 350 D Instructies voor reparatie - Pagina 8

Blader online of download pdf Instructies voor reparatie voor {categorie_naam} Atlas Copco PH 350 D. Atlas Copco PH 350 D 8 pagina's.

1
Mounting the
Fit the bearing end plate (2). If necessary,
nosepiece
with aid of a plastic hammer.
2
Insert the washer. First insert a pair of disk
springs with the vault facing upward, then
one pair facing downward, and again one
pair facing upward. Insert another washer.
3
Fit the gasket. Mount the nosepiece (1)
and secure it with the Allan screw.
Test Run
Test run the machine and pay attention to noises.
Check the direction of rotation!
Let the machine run-in.
Carry out a percussion test.
Electrical Test
Perform an electrical test on the machine (see chapter Electrical and Mechanical Test Instructions).
Repair Instructions No. 162.11/95
PHD 26/ PH(D) 38/ PH 240 D/ PH 350 (D)
1
2
3
PAGE
7
6