The complete set of extendable plastic window panel comes in 3 pieces. The length of
the panel can be extended to suit the window space. Place the plastic window panel
on the window space. Install the round adaptor to the hole on the panel. Connect the
exhaust hose through the hole on the panel allowing the exhaust air flow outside the
room.
(ii)Wall installation (Permanent Mounting)
WALL INSTALLATION
1. Exhaust Port
2. Vent Connecter
3. Exhaust Hose
4. Round Adapter
NOTE: Round adaptor mounts on inside wall.
1) Drill a hole (about dia.135mm) in the wall/glass to fit the round adaptor. It is
recommended to ask qualified technician to drill the hole to ensure safety and to
avoid cutting into a support beam or electrical wires.
2) Insert the round adaptor through the hole and mark the screw positions on
wall/glass.
3) Remove the round adapter and drill four screw holes at these marks.
4) Mount the round adaptor and secure with the screws.
5) Twist the exhaust hose into the round adapter clockwise until it is secured.
6) When not in use, unscrew the exhaust hose from the round adapter and place the
Round adapter
8