Fig 4. Hitch in transport position
2. Press the 'POWER' button on the in-
cab control panel to the, The visual Led
will pulsate GREEN and activate an audi-
ble buzzer (continuous tone) in the ma-
Figure 5
chine cab (
NOTE: If no further action is taken
within 5 seconds the unit will
automatically 'LOCK OUT', the
indicators will go out and the green
LED light will return to a constant
green light.
Fig 5. Switching control box on
3. Activation of cylinders:
Press the 'CONTROL' button within 5 sec-
onds from switch on. The status indicator
light will illuminate to a flashing red sig-
nal and the buzzer will also change from
a continuous tone to a pulsating tone.
This indicates that a positive supply is
being sent to the solenoid valve, which in
turn operates the both lock cylinder.
QMS 22
REV: D - JAN2012
Dromone Multi– Lock Quick Coupler
).
Dromone Multi– Lock Quick Coupler
Fig 6. Press 'CONTROL'
NOTE: After 'CONTROL' button is
pressed, the system will activate a
warning signal at 55 seconds, and
after 60 seconds the hitch will reset
to a closed position.
4. Manoeuvre the 'MULTI-LOCK Quick
Coupler' to line it up with the bucket or
implement to be picked up (
5. Lower the
'MULTI-LOCK Quick Coupler downwards
and slide forward to engage the front
jaw of the 'MULTI-LOCK Quick Hitch'
over the nearest bucket pin. Rotate the
'MULTI-LOCK Quick Hitch' clockwise to
line up the second bucket pin (furthest
from mach.)
10
Button
Figure 7
)
Fig 7. Manoeuvring
into bucket
Author:EOD