Daikin ARC417A Handmatig - Pagina 2
Blader online of download pdf Handmatig voor {categorie_naam} Daikin ARC417A. Daikin ARC417A 8 pagina's. Self-diagnosis by remote controller
Self-Diagnosis by Remote Controller (Residential Air-conditioner)
In case of ARC447A
[Check Method]
With the wireless remote controller supplied with the unit, or
sold separately, malfunction codes by failure diagnosis can be
confirmed. (hold the timer cancel button down for 5 seconds.)
Timer cancel
button
1. Hold the timer cancel button down for 5 seconds, with the
remote controller set toward the indoor unit.
2. The temperature display on the remote controller changes
to the error code display and a long beep notifies this
indication change.
Note:
To cancel indication of malfunction code, hold the timer
cancel button down for 5 seconds.
The code display also cancels itself if the button is not
pressed for 1 minute.
In case of
ARC455A, ARC452A, ARC433B, ARC423A, ARC417A
[Check Method 1]
1. When the timer cancel
button is held down for 5
ON
ON
seconds, a "00" indication
flashes on the temperature
display section.
SENSOR
POWERFUL
2. Press the timer cancel
MODE
button repeatedly until a
QUIET
continuous beep is
generated
ON
The code indication
OFF
changes in the sequence
shown below, and notifies
TIMER CANCEL button
with a long beep.
<In case of ARC433B67, 68, 69, 76>
No.
Code
No.
Code
00
C7
1
12
U4
H8
2
13
F3
J3
3
14
E6
A3
4
15
L5
A1
5
16
A6
C4
6
17
E5
C5
7
18
F6
H9
8
19
C9
J6
9
20
U0
UA
10
21
E7
A5
11
22
Note:
1. A short beep and two consecutive beeps indicate non-
corresponding codes.
2. To cancel the code display, hold the timer cancel button
down for 5 seconds. The code display also cancels itself if
the button is not pressed for 1 minute.
[Check Method 2]
1. Press the 3 buttons (TEMP
, TEMP
MODE) simultaneously to enter the
diagnosis mode.
The figure of the ten's place blinks.
Try again from the start when the figure
does not blink.
2. Press TEMP
figure until you hear the sound of "beep" or
"pi pi".
3. Diagnose by the sound.
"1 short beep" : The figure of the ten's place
does not accord with the malfunction code.
"2 short beep" : The figure of the ten's place
accords with the error code but the one's not.
"1 long beep" : The both figures of the
ON/OFF
ten's and one's place accord with the
TEMP
malfunction code.
FAN
4. Press the MODE button.
COMFORT
SWING
The figure of the one's place blinks.
CANCEL
TIMER
RESET
5. Press the TEMP button.
Press TEMP
figure until you hear the sound of "long beep".
No.
Code
6. Diagnose by the sound.
H0
23
"1 short beep" : The figure of the ten's
E1
24
place does not accord with the
P4
25
L3
malfunction code.
26
L4
27
"2 short beep" : The figure of the ten's place
H6
28
accords with the error code but the one's not.
H7
29
"1 long beep" : The both figures of the ten's
U2
30
and one's place accord with the error code.
UH
31
EA
32
7. Determine the malfunction code.
AH
33
The digits indicated when you hear the
"long beep" sound are error code.
8. Press the MODE button to exit from the
diagnosis mode.
The display "
mode.
,
9. Press the ON/OFF button twice to return
to the normal mode.
Note:
When the remote controller is left untouched
for 60 seconds, it returns to the normal mode.
or
button and change the
or
button and change the
" means the trial operation