DROPSA 3413012 Gebruiksaanwijzing - Pagina 6
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} DROPSA 3413012. DROPSA 3413012 11 pagina's. Pneumatically driven pump
Disassembly must be effected in the following manner:
1. disconnect the tubing attached to the pump.
2. remove the fixing screws and remove the tank, paying PARTICULAR ATTENTION to models containing a
grease pressure loading spring (it could be under pressure– in this case empty the remaining lubricant
first).
3. remove the pump and any filters.
4. unscrew the pneumatic cylinder of the pump paying PARTICULAR ATTENTION to the loading of the
spring; the component parts of the pump unit can then be disassembled.
In this way all component parts of the pump unit can be removed allowing the disassembly and cleaning of the
release and suction valves.
All pieces should be washed in petrol and lubricated prior to reassembly.
The following should be checked periodically:
VERIFY
The state of lubrication
The oil level
The cleanliness of the suction filter
The cleanliness of the loading/return filter
That the tank is clean and the bottom free from
deposits
The machine does not require any special tools to carry out checks or maintenance tasks, However, it is
recommended that only tools suitable for the tasks and in good condition should be utilised (DPR 547/55) to avoid
injury to persons or damage to machine parts.
3.7
Repairs
The following diagnostic table indicates the main anomalies which may be encountered, the probable causes and
possible solutions.
The anomalies shown are:
• the pump fails to deliver sufficient oil or no oil at all
• the pump fails to deliver oil at the prescribed pressure
In case of doubts and/or problems which cannot be resolved do not attempt to disassemble parts of the machine but
contact the Engineering Department of DROPSA S.p.A.
C20008IE – Pneumatically driven pump - Rev. 0
WORK CYCLES
100
200
400
400
600
February 99
Page 6 of 9