ANLIDAR MyTorq MY8-EP0205L Bedienings- en onderhoudshandleiding - Pagina 9

Blader online of download pdf Bedienings- en onderhoudshandleiding voor {categorie_naam} ANLIDAR MyTorq MY8-EP0205L. ANLIDAR MyTorq MY8-EP0205L 13 pagina's. Dc-type automatic non-carbon-brush with counter series

※Push three seconds to enter the selection ) SL===SC===At===Ht===Lt===LL===Ns===Rn===Rt <Confirm>
Function Name
SL
SC
At
RC
SP
Ht
Lt
LL
Ns
Rn
Rt
Backward to Count-Up
LC
UN
Ln
En Wrong Set-Up
Buzzer
Dt Standby Time
Tt Working Time for a
set of screwdriver
※RC=0 或 SP=L0 No slow start control。
※RC& SP / LL RC(with SP) is exclusive to LL (Only one function is actived on setting menu) 。
※Rt / LL Rt is exclusive to LL (Only one function is actived on setting menu) 。
※In the set-up , if Lt and LL show "02."means 0.02, push P to adjust decimal to become 0.2.
※During operation, LED will show three kinds of colors: OK is green light; NG is red light; standby learning is orange light.
※MY8-EP0103 PCB has three kinds of signal, OUTPUT OK1, OKALL and N.G and is an open collector type.
※Output users need input voltage to drive the buzzer, the input voltage can't be over DC24V 10mA.

Panel Specifications

NO
1
2
3
5
7
6
4
Counting Set-Up instruction
Set up Time and
Value
01-05/UU
Screw List
1-99
Counting number / count-down only
0.1-9.9
Automatic zero time / Signal output time
0.0~9.9
Slow start time
Slow start RPM level L0:100%, L1~L9 (30%~90% ) Rated
L0~L9
speed.
0.1-9.9
Ht time Stop time (Show wrong as screwdriver can't sop at set
time after starting, can be used to test stripped screws
0.01-9.9
Lt time will show wrong as screwdriver stops before Lt after
starting, can test screw is not properly fastened at its position.
0.01-9.9
Reconfirm time after fastening.
Y or N
Ns:Set the function of stopping the screwdriver when any error
message occurs.
Y: Stop the screwdriver when any error occurred meanwhile,
Reverse is OK; Restore by pressing "S" button
N: screwdriver could operate continually when any error
occurred.
Y or N
Rn:Set the count-up mode for the reversion.
Y:taken in count for each reversion;N:Only count once when
reverse
0.01 – 9.99
Rt:Set auto reverse time after the screwdriver shutting off.
1 COUNT
When screwdriver is backward, the number will be back one
---
Keypad LOCK P/S/R button
---
UNLOCK
---
Automatic learning.
Wrong Set-Up, such as Lt>Ht
---
buzz if set-number of screws are not completed in the allotted
Seconds
set time for each screw fastening
buzz if set-number of screws are not completed in the allotted
Minutes
set time for a set screw fastening。
Name
1
Three-Color Light
To Show operating is OK, N.G or in the mode condition.
2
Panel
To show set value, set screws number and other value
Push five seconds: to disable COUNTING FUNCTION
3
Power Switch
CLEAR Push three seconds: CLEAR
4
SELECT Key
Push three seconds: Enter the system
5
Up Key
When entering the system, this key increases value
6
Down Key
When entering the system, this key decreases value
7
Reset
Restore to factory settings
S+P
Automatic learning.
UP+P
Waiting time mode
UP+DOWN
Buzzer mode
If press together to enable P/R/S button, and then press again
S+UP
to disable P/R/S button.
Description
8
Function
Buzz Time/ Light
---
---
---
---
Five buzz and LED red flash
Two buzz and LED red flash
---
---
LED keeps flash of light
Three buzz and LED red flash.
Automatically show En
Lasting buzz s and LED red flash
Lasting buzz s and LED red flash
Factory
default
settings
---
05
1.0
0.0
L0
2.0
0.00
0.00
---
---
---
---