15 Job
16 Sequence
17 Program unit
18 Program Name
19 Select Tool
20 Torque
21 Torque unit
22 Fastening time
23 Fastening thread
24 Screw count
25 INC/DEC
26 Status
27 Tool Stop Status
28 Tail
29
30
Item 1 to 28 are separated by "," (ASCII 0x2c)
Remark
{CMD100,2019,11,26,16,24,48,2144,7582,0,100,}
4. {CMD100} Data format/example
Field
1 Header+CMD
2 Year
3 Month
4 Date
5 Hour
6 Minute
7 Second
8 Check Sum
9 Key Code
10 Device Name
11 Instruction number
12 Tail
13
14
1.Item 1 to 12 are separated by "," (ASCII 0x2c)
Remark
2.Reply to CMD100 when the time is inconsistent or repeat {DATA100}
4. {DATA101} Data format/example
{DATA101,00.612,000.25}
Field
1 Header+CMD
2 Fastening time
3 Torque
4
5
1.Item 1 to 3 are separated by "," (ASCII 0x2c)
Remark
2.WIFI and Ethernet will not output {DATA101,...} data.
RS-232C 9 Pin Female (DCE) to PC or PLC (DTE)
Communication interface :
Connection :
※ The external device can judge the 14th field (Device Count) of response data to check if there is any new update tightening data from DATA100.
Remark
If the Device Count increased which means there is a new record.
01~50
01~50
01~99
1~6 Bytes
01~09
Please refer tothe specification of screwdrivers
0~3
0000.0000~0009.9990
0000.0000~9999.9999
00~99/00~99
0~1
OK,NGQ,NGC,OKALL,NG-F,NS-F
0~9,A~H
}
Parameter
Value
{CMD100
0001~9999
01~12
01~31
00~23
00~59
00~59
0000-9999
0000-9999
0~1
1~255
}
Parameter
Value
{DATA101
00.000~99.999
Please refer tothe specification of screwdrivers}
USB
1.Barcode scanner
2.Connection method
String
2 Byte
String
2 Byte
String
2 Byte
String
6 Byte
String
2 Byte
String
9 Byte
String
1 Byte
String
9 Byte
String
9 Byte
String
5 Byte
String
1 Byte
String
5 Byte
String
1 Byte
String
1 Byte
{DATA100, ..... }Total:166 Byte,28 Field
Data Type
String Length
String
7 Byte
String
4 Byte
String
2 Byte
String
2 Byte
String
2 Byte
String
2 Byte
String
2 Byte
String
4 Byte
String
4 Byte
String
1 Byte
String
3 Byte
String
1 Byte
{CMD100, ..... }Total: 45Byte,12 Filed
Data Type
String Length
String
8 Byte
String
6Byte
String
7Byte
{DATA101, ..... }Total: 23Byte,3 Filed
WIFI
1.WIFI module
2.Connection method
99-100
Selected Job
102-103
Selected Sequence
105-106
Selected Unit Program
Setup program name, it can choose number、
108-113
capitals and lower case letters、number for program name.
115-116
Selected Tool (Current activated screwdriver)
118-126
Shutoff troque(example:0000.0000)
128
Torque unit(0: kgf.cm, 1: N.m, 2: lbf.in, 3: kgf.m)
130-138
Fastening time(ms)
140-148
Fastening thread
150-154
The numbers of remaining screws / Total screws
156
INC/DEC(0: INC, 1: DEC)
Fastening status
OK:Each time when the fastening is complete.
NGQ: stop torque is less than L/more than H.
NGC: stop number of turns is less than L/more than H.
OKALL:Each time when a batch is complete.
158-162
NG-F:Sequence incomplete
1(Number represents step,5 step)
NS-F:Press Confirm/Enter for next action.
1(Number represents step,5 step)
Less than 5 Bytes ,fill the underline"_".
Tool Stop Status(0: None , 1:NS, 2:AS, 3:E3, 4:E4, 5:E5, 7:E7, 8:E8,
164
9:E9, A:EPC, B:ESC, C:ES, D:Er, E:C1, F:C2, G:C4, H:C5)
166
Tail
ASCII code LF
ASCII code CR
Position
Description
1-7
Header+Command code
9-12
Year
14-15
Month
17-18
Date
20-21
Hour(24 hours)
23-24
Minute
26-27
Second
29-32
YEAR+MONTH+DAY+HOUR+MINUTE+SECOND = Check Sum
34-37
Check Sum+5438=Key Code
39
Device Name(0: AMS, 1: DAS)
41-43
Instruction number
45
Tail
ASCII code LF
ASCII code CR
Position
Description
1-8
Header+Command code
10-15
Fastening time
17-23
Torque(Torque value varies according to the torque unit)+Tail
ASCII code LF