Physical Properties
• Outside dimensions are 5.9" x 3.6" x 2.8" (150 mm x 92 mm x 72 mm).
• The drying tray has two compartments: the forward drying area measures 3.2" x 2.6" x 1.0"
(80 mm x 65 mm x 24 mm), and a small Dry-Brik
• Weight as shipped is approximately 1 lb, 4 oz (582 g).
Power Supply
Input: 100-240 volts AC, 50/60 Hz, 1.0A max. Output: 24 VDC at 15W max. Zephyr power supplies are
interchangeable with Dry & Store
standards, and carry GS (Germany), PSE/JET (Japan), C-Tick (Australia/New Zealand), and SABS (South
Africa) certifications.
Operating Features
• Ball-bearing fan continuously circulates warm, dry air for the entire operating cycle, causing moisture
to move out of the hearing instruments by diffusion. A desiccant in the airflow path strips the moisture
out of the air, ensuring continuous dry operation.
• Dry & Store will remove the moisture from cerumen, making it easier to remove.
• Zephyr turns off automatically after 8 hours unless the
• Batteries do not have to be removed from hearing devices.
• Dry & Store is not designed to diagnose, prevent, monitor, treat, or alleviate disease.
Desiccant
A disposable Dry-Brik
Preparations for Use on page 4.)
Rechargeable Canister Desiccant (optional)
A small number of international configurations are shipped with an optional metal canister desiccant
instead of a Dry-Brik. The protective label should be removed from both sides before use. As moisture
is adsorbed by the desiccant, the indicator will change from orange (good) to green (bad), or from blue
(good) to light pink (bad), depending on the model. The color change signals that the desiccant can
no longer adsorb moisture. To restore function, place the metal can in a conventional oven for 3 hours
or more at a temperature of 105°-150°C (225°-300°F). The color will change back to orange or blue.
Warning: Never place metal in a microwave oven! After recharging, allow the hot metal can to cool
before use. Best results will occur if the can is covered by a glass during the cooling period.
Zephyr
Global and are CE Marked. They are certified to ETL, UL, and CSA
®
, which must be replaced every two months, is included with each Zephyr. (See
®
by Dry & Store
compartment is in the rear of the tray.
®
/
button on the side is pressed.
on
off
®
Rev D