Ook voor Daikin R32 Split Series: Installatiehandleiding (17 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (17 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (20 pagina's), Installatiehandleiding (14 pagina's), Installatiehandleiding (14 pagina's), Bedieningshandleiding (16 pagina's), Bedieningshandleiding (8 pagina's), Installatiehandleiding (17 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (20 pagina's), Installatiehandleiding (20 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (14 pagina's), Installatiehandleiding (14 pagina's), Installatiehandleiding (16 pagina's), Installatiehandleiding (17 pagina's), Installatiehandleiding (20 pagina's), Installatiehandleiding (13 pagina's)

Daikin R32 Split Series Bedieningshandleiding

5 Operation

b
Screws (field supply)
c
Wireless remote control holder
1 Choose a place where the signals reach the unit.
2 Attach the holder with screws to the wall or a similar location.
3 Hang the wireless remote control on the holder.
4.2

To insert the batteries

The batteries will last for about 1 year.
1 Remove the back cover.
2 Insert both batteries at once.
3 Put the cover back.
1
3
2
AAA.LR03
4.3
To switch between Fahrenheit and
Celsius
Prerequisite: Change this setting only when the temperature is
displayed.
1 Press
and
simultaneously for about 5 seconds.
Result: The setting changes.
4.4

To turn on the power supply

1 Turn the circuit breaker on.
Result: The flap of the indoor unit will open and close to set the
reference position.
5
Operation
5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.
Operation mode
(a)(b)
Cooling
▪ Outdoor temperature: –10~48°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
Heating
▪ Outdoor temperature: –15~24°C DB
▪ Indoor temperature: 10~30°C DB
(a)
Drying
▪ Outdoor temperature: –10~48°C DB
▪ Indoor temperature: 18~32°C DB
▪ Indoor humidity: ≤80%
(a)
A safety device might stop the operation of the system if the unit
runs outside its operation range.
(b)
Condensation and water dripping might occur if the unit runs
outside its operation range.
5.2

When to use which feature

You can use the following table to determine which features to use:
Feature
Basic features
Operation manual
6
Operation range
Tasks
Feature
To start/stop the system and to set the
Operation modes and
temperature:
temperature
▪ Heat up or cool down a room.
▪ Blow air in a room without heating or
cooling.
▪ Decrease the humidity in a room.
▪ In Automatic mode, automatically
select an appropriate temperature
and operation mode.
To adjust the airflow direction (swing or
+
Airflow
fixed position).
direction
To adjust the amount of air blown into
Airflow rate
the room.
To run more quietly.
Advanced features
To use the system when you are also
Econo
using other power-consuming
appliances.
To save energy.
To provide a comfortable airflow that
Comfort
does NOT come in direct contact with
people.
To cool down or heat up the room
Powerful
quickly.
To automatically turn ON or OFF the
ON timer +
OFF
system.
timer
5.3
Operation mode and temperature
setpoint
When. Adjust the system operation mode and set the temperature
when you want to:
▪ Heat up or cool down a room
▪ Blow air in a room without heating or cooling
▪ Decrease the humidity in a room
What. The system operates differently, depending on the user
selection.
Setting
The system cools down or heats up a
Automatic
room to the temperature setpoint. It
automatically switches between cooling
and heating if necessary.
The system decreases the humidity in a
Drying
room.
The system heats up a room to the
Heating
temperature setpoint.
The system cools down a room to the
Cooling
temperature setpoint.
The system only controls the airflow
Fan
(airflow rate and airflow direction).
The system does NOT control the
temperature.
Additional info:
▪ Outside temperature. The system's cooling or heating effect
decreases when the outside temperature is too high or too low.
Tasks
Description
FTXP20~35M5V1B/B9
R32 Split series
3P520336-6T – 2021.12