DRYDEN AQUA 90028 Bedieningshandleiding - Pagina 6

Blader online of download pdf Bedieningshandleiding voor {categorie_naam} DRYDEN AQUA 90028. DRYDEN AQUA 90028 20 pagina's.

DRYDEN AQUA 90028 Bedieningshandleiding

7. Installation

6.1. Replacing the flapper & indicator assembly in
1.5"(DN40) 2" (DN50) and 2.5" (DN65) installations
For the FlowVis Digital (FV-D) to function on FlowVis
models DN40, DN50, and DN65, it will be necessary to
replace the Flapper and its attached red indicator with
the one provided in the FlowVis digital (FV-D ) packing
box (see Fig.1.4 on page 4) - regardless of whether the
FlowVis unit itself is new or already installed. This is a
simple procedure that will take less than 2 minutes;
however, it is important to reassemble the unit exactly
as shown below.
Procedure:
1.
Release each of the two spring legs from the location tabs - this will
remove the tension from the spring. See Fig.2.3 above.
2.
Slide the Hasteloy pivot pin to completely remove it from the lid.
3.
Discard the existing gray Flapper with its attached red indicator.
4.
Pay attention to the orientation of the spring when reassembling the unit.
5.
Install the new Flapper and Indicator following a reversal of the
disassembly procedure. Note, you may find it easier to place the spring's
legs over their location tabs before sliding the pin.
Scan QR code
to watch procedure
video
Fig 2.3
Spring legs location tabs
6