DS Stoves FP16 Gebruikershandleiding - Pagina 5
Blader online of download pdf Gebruikershandleiding voor {categorie_naam} DS Stoves FP16. DS Stoves FP16 13 pagina's. High efficiency hopper fed coal insert
Clearance Requirements
Fireplace Insert Chimney,
Clearance Requirements and
Specifications
1. Insert must be installed in and existing masonry
or factory built fireplace. Maintaining all clearance to
combustibles.
2. Insert must be installed on a noncombustible
surface.
3. Locate and read clearance to combustibles in
manual before installing unit. The most important
consideration in installing your insert is adequate
clearance between the insert and any combustible
surface. An Insert that is located to close to a man-
tel, trim, furniture or any combustible materials may
cause a fire.
4. A noncombustible base must extent at least 16"
beyond front of insert and 8" beyond each side of
load and ash doors.
5. Do not connect this unit to a chimney flue serv-
icing other appliances. A "6" Class A" chimney liner
must extend from insert to top of chimney. It is rec-
ommended to wrap liner with foil faced insulation to
enhance performance of chimney.
Hot Air Regulator with Draft Intake
Chain Adjustment
Mantle
Trim
Minimum Clearances to
Combustible Materials
Unit to Sidewall
Unit to Right Side Facing
Unit to Left Side Facing
Unit to Top Facing
Unit to Mantle
Floor Protection in Front of Door
Floor Protection each Side of Door
5
Fireplace
Insert
A - 10"
B - 9"
B - 9"
C - 25"
D - 30"
E - 16"
F - 8"