Tetra
EdgeStrip HO
®

Electrical Connections

NOTE: Refer to the power supply installation instructions for loading and remote mounting information.
NOTE: Do not use connectors pre-filled with silicone grease/mineral base protective grease or use silicone grease
to seal connections.
Connect modules using twist-on wire connectors
1
or in-line (IDC) connectors. Join white wires
together and red striped wires together.
NOTE: Additional supply wire may be necessary to
bridge electrical connections.
To LED System
Power
Supply
Run a wire from the Power Supply and connect to
3
the first LED module on the strip.
Must be used with Tetra
NOTE: All electrical connections should be suitably protected from mechanical damage and the environment. Seal all
connections in locations that may be exposed to water with electrical grade RTV silicone.
24 Volt Power Supplies.
®
Cap all exposed wires with appropriate end caps
2
or apply electric grade (non-conductive) silicone
for additional weather protection.
Connect the red stripe wire (+) of the LED
4
system to the red wire (+) of the power supply.
Connect the white wire (-) of the LED system to
the black or blue wire (-) of the power supply.
NOTE: All electrical connections should be
made within the box sign.
3
Installation Guide
To Power
Supply