DSC PK5500 Handleiding voor installatie-instructies - Pagina 4
Blader online of download pdf Handleiding voor installatie-instructies voor {categorie_naam} DSC PK5500. DSC PK5500 16 pagina's. Power series
Ook voor DSC PK5500: Gebruiksaanwijzing (20 pagina's), Handleiding voor installatie-instructies (9 pagina's), Handleiding voor installatie-instructies (8 pagina's)
Keypad Enrollment
Enter keypad programming by pressing [,][8][Installer's Code][000].
[0] Partition / Slot Assignment
Digit
1st
Partition Assignment (0=Global Keypad)
2nd
[1]-[5] Function Key Assignment
Function Key
[1]
Function Key 1 Assignment
[2]
Function Key 2 Assignment
[3]
Function Key 3 Assignment
[4]
Function Key 4 Assignment
[5]
Function Key 5 Assignment
Keypad Function Keys
Refer to your system installation manual for a complete list of all function key options available for your system.
[00]
- Null
[01]
- Partition 1 Select
[02]
- Partition 2 Select
[03]
- Stay Arm
[04]
- Away Arm
[05]
- No Entry Arm
[06]
- Chime On/Off
[07]
- System Test
*Available only on the PC1616/PC1832/PC1864 version 4.2 or higher.
Keypad Programming
Enter keypad programming by pressing [,][8][Installer Code][,]
[001]-[064] Zone Label 1 to 64
ex. For Zone 1 enter section [001], for Zone 2 enter section [002] etc. Default: "Zone 1" - "Zone 64"
Section
Zone
[001] to [064]
1 to 64
Option
Slot Assignment
Button
Valid Range
00 to 32
00 to 32
00 to 32
00 to 32
00 to 32
[08]
- Bypass Mode
[09]
- Trouble Display
[10]
- Alarm Memory
[11]
- User Programming
[12]
- User Functions
[13]
- Command Output 1
[14]
- Command Output 2
[15]
- *Global Stay Arm
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I
Valid Range
0 to 8
1 to 8
Default
Function
03
Stay Arm
04
Away Arm
06
Chime On/Off
14
Sensor Reset
16
Quick Exit
[16]
- Quick Exit
[17]
- Activate Stay/Away
[18]
- *Global Away Arm
[19]
- Command Output 3
[21]
- Command Output 4
[22]
- *Global Disarming
[23]
- Bypass Recall
[24]
- Bypass Group Recall
Label
Default
1
I________I
8
I________I
I________I________I
I________I________I
I________I________I
I________I________I
I________I________I
[26]
- Time & Date Program
[27]
- Partition 3 Select
[28]
- Partition 4 Select
[29]
- Partition 5 Select
[30]
- Partition 6 Select
[31]
- Partition 7 Select
[32]
- Partition 8 Select
[33]
- Local PGM Activate