4. Configuration
In factory configuration, the movement detector is configured in
Deterrence (for the reactions of the system see the control panel
installation guide). It is possible to modify the level of alarm using
the following sequence of parameter setting:
Parameter n°
Alarm level
4
Intrusion
Prealarm
Deterrence
Warning
Sequence of
parameter setting
Indicator
lamp for
programming lit
Indicator
lamp for
about
programming
10 sec.
not lit
sequence
To start
Press 4 times
the sequence
depending
press and hold
on the required
the button
parameter
until the LED
number
indicator lamp
goes out
Configuration example: setting the detector for an alarm level
when a prealarm is triggered: parameter n° 4, parameter value 2.
4
Start
Press 4 times
to select
the alarm
level
Parameter value
1
2
3 (factory setting)
4 (the feature is available using control panels
with 2.0.0 version software or later)
about
about
5 sec.
10 sec.
Press and
Press
To end
hold until
the sequence
1 to 4 times
the LED
depending
press and
indicator
on the
hold the
lamp
required
button until
briefly
parameter
the LED
goes out
value
indicator
lamp goes
out
2
Press
Press 2 times
End
once to
to select
accept
the prealarm
selection
level

5. Installation precautions

IMPORTANT: make sure there is a distance of at least 2 meters between
each product, except between two detectors.
The motion detector must be placed:
Perpendicular to the ground, so that
the zone of higher detection is
parallel to the ground.
If the detector is tilted compared
to the ground, the reliability
of operation can be reduced.
parallel
about
2 sec.
With an installation height
from 0.8 to
1.2 m high.
LED
indicator
lamp lit
=
correct
confi -
0.8 m < H < 1.2 m
guration
The motion detector must not be placed:
In an area likely to receive
direct sunlight or a very
powerful light source.
2 s.
env.
Directly on to a metal wall or close to sources of interference
(electricity meters, etc.) or ventilation such as air-conditioning
grilles.
55
parallel
By adjusting the zone of
detection so that the objects
or people moving "cross"
the zone of
detection.
In direction of moving objects
(branches, bushes, flags,
etc.).
GB