Applying Power
Once all wiring is complete, apply power to the
control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power
specifications, see the control panel Installation
Manual .
NOTE: Do not connect the power until all wiring is
complete.

Enrolling the Keypad

Once all wiring is complete, you will need to enter a
2-digit number that tells the system the partition
and slot assignment of the keypad.
If your system has partitions, you will also need to
assign the keypad to a partition (1st digit).
The slot assignment (2nd digit) tells the panel
which keypad slots are occupied. The panel can
then generate a fault when a keypad supervisory
signal is not present. There are eight available slots
for keypads. LCD5500Z / PKP-LCD keypads are
always assigned to slot 1 by default. You will need
to assign each keypad to its own slot (1 to 8).
Enter the following at each keypad installed on the
system:
1. Enter Installer Programming by pressing
[ ][8][Installer Code]
2. Press [000] for Keypad Programming
3. Press [0] for Partition and Slot Assignment
4. Enter a two digit number to specify the partition
and slot assignment.
NOTE: If your system does not have partitions, enter
[1] for the first digit.
1st digit
Enter 0 for Global Keypad
Enter 1-8 for Partition1-8 Keypad
2nd digit
Enter 1-8 for Slot Assignment
5. Press the [#] key twice to exit programming.
6. After assigning all keypads, perform a supervisory
reset by entering [ ][8][Installer Code][902]. The
panel will now supervise all assigned keypads and
enrolled modules on the system.
2
v3.X Keypad Programming
1. From the LCD keypad, enter [ ][8][Installer Code].
2. The keypad will display "Enter Section _ _ _".
3. Now Press the [ ] key. The LCD will display "Enter
LCD Section _ _"
4. Now enter a section as described below for
programming the keypad.
5. Sections [120] - [151] will display "Output Label"
on the top line of the label, and cannot be
changed.
[001] - [064] Zone Labels
Default
Default
Default
Default
Default
Z o n e_ _ _ _ _ 1 _ _ _ _
I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I
Default
Default
Default
Default
Default
Z o n e_ _ _ _ _ 6 4 _ _ _
I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I
[065] Fire Alarm Label
Default
Default
Default
Default
Default
F i r e _ Z o n e _ _ _ _ _
I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I
[066] Fail to Arm Event Message
Default
Default
Default
Default
Default
S y s t e m _ H a s _ _ _ _ _ _
I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I
F a i l e d _ t o _ A r m _ _ _
I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I
[067] Alarm When Armed Event Message
Default
Default
Default
Default
Default
A l a r m _ O c c u r r e d _ _
I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I
W h i l e _ A r m e d _ _ _ <>
I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I _ ___I