could be present on the system:
System Busy
System Troubles
Alarm Memory
Zone Bypassing
Programming
The Advanced Techniques
Zone Bypassing
The zone bypassing function is used when access is needed to part of the protected area while the
system is armed.
Bypassed zones are automatically cancelled each time the system is disarmed and must be reapplied
before the next arming.
To bypass zones from an LED or Fixed Message LCD5501Z keypad:
Start with the system in the Ready state. Enter [*][1][Zone(s) to be bypassed]# E.G. To bypass zone 03,
press *103#. Then you can Arm your system as you normally do.
To add or change passwords in alarm system
Your alarm system can have multiple passwords. You can add or change a password. You can
calso change the master password.
Each password has a location number. The master password is in location 40. The others are
numbered as: 01, 02, 03...etc.
You may have already programmed in more than one password.
To see which locations currently have passwords:
*5 XXXX (XXXX is the current master password).
A light will go on next to the location number, indicating there is a access code
assigned to the location. E.G. If lights 1 and 2 are on, then there is an access code
assigned to locations 01, and 02.
code is for these locations.)
To change master password (which is allocated to code location 40)
*5 XXXX 40 YYYY #
(XXXX is current master password, YYYY is new master password)
To add or change secondary passwords:
*5 YYYY 01 ZZZZ #
(YYYY is master password) ZZZZ is new secondary password in allocated to code
Location 01)
To add/change multiple passwords at one time:
*5 YYYY 01 ZZZZ
(YYYY is master password) ZZZZ is new secondary password in allocated to code
location 01, AAAA is new secondary password allocated to code location 02, etc.)
To erase a code:
Enter *5 YYYY (YYYY is master password), enter location number (to be deleted) 01 to 32,
Press [****] (...the asterisk key for times, then) [#] to return to the Ready state.
The Master code cannot be erased.
Setting the System Date and Time
To set the system time, enter [
10 consecutive digits:
• Enter the Time in Hours and Minutes using the 24-hr format (00:00 to 23:59).
• Enter the Date in Months, Days and Years (MM DD YY).
(There is no (easy) way of determining what the assigned access
02 AAAA 03 BBBB #