DSE DSE704 Bedieningshandleiding - Pagina 13
Blader online of download pdf Bedieningshandleiding voor {categorie_naam} DSE DSE704. DSE DSE704 15 pagina's. Autostart control module
- 1. Table of Contents
- 1. 1 Description of Operation
- 1. Manual Mode Operation
- 1. Automatic Mode of Operation
- 1. Warnings
- 1. Shutdowns
- 2. 2 Configuration Instructions
- 3. 3 Configuration Tables
- 4. 4 Terminal Description
- 5. 5 Specification
- 6. 6 Solid State Outputs
- 7. 7 Dimensions
- 8. 8 Typical Connections
5 SPECIFICATION
Cranking Dropouts:
Alternator Input Range:
Mains Input Voltage
Alternator Input Frequency:
Mains Frequency
Auxiliary Outputs:
Operating Temperature Range:
Applicable Standards
Deep Sea Electronics plc reserve the right to change specification without notice.
057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR
DC Supply:
8 Volts to 35 Volts DC Continuous.
Able to survive 0 Volts for 50 mS, providing supply was at
least 10 V before dropout and supply recovers to 5 Volts.
This is achieved without the need for internal batteries.
Max. Current:
Operating 50mA
Standby 10mA
75 Volts (ph-N) to 277 Volts (ph-N) AC (+20%)
15 – 277 Volts (ph-N) AC (+20%)
50 - 60 Hz at rated engine speed
(Minimum: 75V AC Ph-N)
(Crank Disconnect from 15V Ph-N @ 20Hz)
Overspeed +14% (+24% overshoot)
Underspeed –20%
50 – 60 Hz
Start Output:
1.2 Amp DC at supply voltage.
Fuel Output:
1.2 Amp DC at supply voltage.
1.2 Amp DC at supply voltage.
Dimensions:
125mm x 165mm x 28 mm
Charge Fail:
12 Volts = 8 Volts CF 24 Volts = 16 Volts CF
-30°C to + 70
Compliant with BS EN 60950 Low Voltage Directive
Compliant with BS EN 50081-2: 1992 EMC Directive
Compliant with BS EN 61000-6-4: 2000 EMC Directive
Compliance to European Legislation
Registered Component for USA & Canada
0
C
- 13 -