ATSI RMBC64-24D HAWK Gebruikershandleiding - Pagina 13

Blader online of download pdf Gebruikershandleiding voor {categorie_naam} ATSI RMBC64-24D HAWK. ATSI RMBC64-24D HAWK 13 pagina's. Hawk 3 stage electronic battery charger

RMBC64/24D ELECTRONIC BATTERY CHARGER
Trouble Shooting.
Mains
Plug
RMBCPL
MAINS
POWER
LEAD
Problem
Charger no power.
Mains neon light
not illuminated.
Charger has power.
Neon mains light
illuminated but not
charging. (No LED's
flashing)
Charger green LED's
flashing but red LED's
will not illuminate when
start button is pressed.
Charger green LED's
flashing but red LED's
will not illuminate when
button is pressed.
* Note
RMBC64/24D
HAWK DOUBLE
BATTERY CHARGER
Possible Cause
No mains power
Charger fuse blown
RMBC24 lead not
connected
HAWK
fully charged.
The RMBC64/24D is designed to warn the operator that power is ON
by the mains neon light being illuminated.
The neon light is in front of the fuse to warn the operator NOT to open the
fuse holder until the mains has been SWITCHED OFF, to avoid an
electrical shock.
HAWK
BATTERY
HAWK
BATTERY
RMBCL
HAWK
CHARGER
LEAD
Possible Remedy
Check mains plug.
Replace 13Amp fuse.
Check power from source.
WARNING CHARGER MUST BE
SWITCHED OFF FROM THE MAINS
BEFORE OPENING FUSE HOLDER
Replace fuse with RMFA8
* see note
Check both ends are connected
correctly and the rings are locked
on the Amphenol plug and socket.
Allow battery to cool for 1 hour
Note it is not recommended to use
full charge again when battery is
fully charged.
Trickle charge is sufficient to keep
the battery topped up from full.