DSPPA DSP1502 Gebruiksaanwijzing - Pagina 3
Blader online of download pdf Gebruiksaanwijzing voor {categorie_naam} DSPPA DSP1502. DSPPA DSP1502 8 pagina's. Public address system phased-array sound column
* Public Address System
1. Product Description
The phased-array sound column is a new type of public address system. By applying the electronic and
digital signal processing (DSP) technologies, it can simulate the directivity from different shapes of
sound columns, while the inherent performances of the sound column will not be affected, e.g. rated
power, range of effective frequency response and max. sound pressure level.
With DSP technologies, we may operate from the remote controller to change the directivity of speaker
system at some extent. This is suitable for loud speaking in a hall where the building acoustics is poor
(especially long reverberation time). This product is most suitable for the hardware (sound box, DSP
processor) of the loudspeaker system in sports venues (where the volume is large, the building
acoustics is poor, the reverberation time is long and the sound is muddy), so that it can be combined with
special software to make the controllable sound cover useful area (auditoria, etc) correctly and prevent it
from diffusion to useless area (e.g. ceiling, door or window). In this case, it can reduce the investment in
acoustic decorations in venues and decrease the energy loss caused by loudspeaker system. This leads
to reduced investment in both the acoustic decorations and sound system in the sports venue.
2. Functions
Acoustically simulate the sound columns of different shapes, e.g. inclined, concave, convex and
more complicates shapes.
Active sound column with inbuilt digital signal processor and digital power amplifier, so that it is
no need for external power amplifier.
Compatible with line signal input (300mV), line signal output (200mV) and broadcasting power
signal input with fixed voltage (70V or 100V).
Volume, tone and other parameters of the sound column adjustable.
The LED array screen on the right lower of the sound column can display different parameters
and messages.
Operate from infrared remote controller.
Compact size, easy installation and high electroacoustic sensitivity.
3. Description of Remote Controller Keypad
Key
Function
Power ON/OFF
Sound ON or
OFF
Equilibrium
EQ
adjustment
Increase
AN+
directivity angle
Decrease
AN-
directivity angle
V+
Increase volume
Decrease
V-
volume
FOCUS+
Focus backward
FOCUS-
Focus forward
S Key
Select sensitivity
Operation
One touch of this key slightly
One touch of this key slightly
One touch slightly to enter into equilibrium
interface. See Page 4 for operating methods.
One touch to increase by 1° . Hold down for 3s
to increase continuously
One touch to decrease by 1° . Hold down for 3s
to decrease continuously
One touch to increase by 1 level. Hold down for
3s to increase continuously
One touch to decrease by 1 level. Hold down
for 3s to decrease continuously
Every touch to move 1m backward. Hold down
for 3s to move continuously
Every touch to move 1m forward. Hold down for
3s to move continuously
One touch to view sensitivity; hold down to
select sensitivity value
It takes approx. 5s for startup.
14-section equilibrium;
amplitude ± 12dB
Max. angle: +45°
Min. angle: -45°
Max. volume: 32 levels
Min. value: 0
Nearest: -30m
Farthest: +30m
0dB, -6dB and -10dB available
for selection
1
Operating Instructions
Remarks