Absolute Process Instruments API 4400 G Snelstarthandleiding

Blader online of download pdf Snelstarthandleiding voor {categorie_naam} Absolute Process Instruments API 4400 G. Absolute Process Instruments API 4400 G 2 pagina's. Dc to dc math function transmitters, isolated

Absolute Process Instruments API 4400 G Snelstarthandleiding
DC to DC Math Function Transmitters, Isolated
Input:
0-100 mV to 0-10 VDC or 0-1 mA to 0-20 mA
Output:
0-1 V to ±10 VDC or 0-1 mA to 4-20 mA
O Add, Subtract, or Average up to 4 DC Inputs
O Factory Set Custom I/O Ranges
O Easy-to-Install Plug-In Design
O Full 2000 V Input/Output/Power Isolation
O Input and Output LoopTracker
LEDs
®
O Output Test Button
Applications
Q Add, Subtract, Average Flow Signals
Q Average Multiple Signals
DC Input Ranges
Factory configured, please specify each input range
Minimum
Maximum
Voltage:
0-100 mVDC
0-10 VDC
Bipolar voltage: ±100 mVDC
±10 VDC
Current:
0-1 mADC
0-20 mADC, 4-20 mA
Popular ranges: 0-1 VDC, 0-5 VDC, 1-5 VDC, 0-10 VDC,
±5 VDC, ±10 VDC, 0-20 mA, 4-20 mA
System voltages must not exceed socket voltage rating
Inputs are converted to a percentage and then the math
function is applied. Consult factory for mixed ranges, special
ranges or non-standard functions.
Input Impedance
Voltage:
100 kΩ per volt nominal
50 Ω nominal
Current:
Input Voltage Burden (Current)
1.0 V
maximum
RMS
Balance Between Inputs
Better than ±0.5% of span
LoopTracker
Variable brightness LEDs indicate I/O loop level and status
DC Output Range
Factory configured, please specify output range or consult fac-
tory. See table on other side for common ranges.
Voltage, 10 mA max.: 0-1 VDC to
Bipolar voltage:
±1 VDC to
Current:
0-1 mADC to
0-20 mADC
20 V compliance, 1000 Ω at 20 mA
Output Calibration
Multi-turn zero and span potentiometers for output
±15% of span adjustment range typical
Output Loop Power Supply
20 VDC nominal, regulated, 25 mADC, max. ripple <10 mV
Output Test
Sets output to test level when pressed
Adjustable 0-100% of span
Output Ripple and Noise
Less than 10 mV
RMS
Linearity
Better than ±0.1% of span
Ambient Temperature Range and Stability
–10°C to +60°C operating ambient
Better than ±0.02% of span per °C stability
Response Time
100 milliseconds typical, faster response times are available
DF option: 1 millisecond response time
Isolation
2000 VRMS minimum
Full isolation: power to input, power to output, input to output
Individual inputs are single-ended (common ground)
Housing and Sockets
IP 40, requires installation in panel or enclosure
API 011 or API 011 FS socket
Socket mounts to 35 mm DIN rail or can be surface mounted
Power
Standard:
115 VAC ±10%, 50/60 Hz, 2.5 W max.
P option:
85-265 VAC 50/60 Hz, 60-300 VDC, 2.5 W
A230 option: 230 VAC ±10%, 50/60 Hz, 2.5 W max.
D option:
9-30 VDC, 2.5 W typical
A
P
BSOLUTE
ROCESS
Variable Brightness
Input LED
Output Test Button
Output Test Adjust
Output Span
Output Zero
Variable Brightness
Output LED
Description
The API 4400 G through API 4408 G are factory configured to
accept two to four DC voltage or current inputs and provide
an optically isolated DC voltage or current output that is pro-
portional to the sum, average and/or difference of the inputs
depending on the model.
The A, B, C, and D inputs should be the same type, and mixed
input ranges are allowable. Consult the factory when selecting
mixed input ranges.
Inputs are converted to a percentage and then the math
function is applied. Consult the factory if true voltage math
0-10 VDC
is required.
±10 VDC
The API 4400 G series uses no transformers or choppers in the
signal path for best noise immunity and freedom from AC arti-
facts in the output. The inputs are not isolated from each other
and use the same signal common connection. The modules do
features full 3-way (input, output, power supply) isolation. A
wide bandwidth 1 millisecond response model is available for
high-speed applications.
RMS
Common ranges as well as custom ranges are possible.
Consult the factory for assistance with special ranges.
Model
API 4400 G
API 4401 G
API 4402 G
API 4403 G
API 4404 G
API 4405 G
API 4406 G
API 4407 G
API 4408 G
Power options—add to end of model number
A230
230 VAC
P
85-265 VAC or 60-300 VDC
D
9-30 VDC
Options—add to end of model number
DF
Fast response, 1 millisecond nom. response time
DF option will cause output noise levels greater
than standard specifications.
U
Conformal coating for moisture resistance
Accessories—order as separate line item
API 011
11-pin socket
API 011 FS 11-pin finger-safe socket
API CLP1
Module hold-down spring for high vibration or
mobile applications
I
NSTRUMENTS
2.38"
1.75"
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
H H H H H
H H H H H H
Made in USA
Function
Factory Configured Input
(A + B + C + D) / 4
Specify 4 input ranges
(A + B + C) / 3
Specify 3 input ranges
(A + B) / 2
Specify 2 input ranges
(A + B + C – D) / 3
Specify 4 input ranges
(A + B – C – D) / 2
Specify 4 input ranges
A – B – C – D
Specify 4 input ranges
(A + B – C) / 2
Specify 3 input ranges
A – B – C
Specify 3 input ranges
A – B
Specify 2 input ranges
1220 American Way Libertyville, IL 60048
Phone:
800-942-0315
API 4400 G through API 4408 G
Free Factory
I/O Setup!
api-usa.com/4400
LoopTracker
API exclusive features include two LoopTracker LEDs (green for
input, red for output) that vary in intensity with changes in the
process input and output signals. These provide a quick visual
picture of your process loop at all times and can greatly aid in
saving time during initial startup and/or troubleshooting.
Output Test
An API exclusive feature includes the Functional Test Button
to provide a fixed output (independent of the input) when held
depressed. The output test level is adjustable from 0 to 100%
of output span.
The functional test button greatly aids in saving time during
initial startup and/or troubleshooting.
Installation
The API 4400 G through API 4408 G plug into an industry stan-
dard 11-pin octal socket sold separately. Sockets API 011 and
finger-safe API 011 FS allow either DIN rail or panel mounting.
The plug-in design, 3-way isolation, and robust electronics
allows the module to be quickly hot-swapped without removing
the power or I/O signals.
Output
Factory configured,
specify output range
API 011 FS
API 011
300 V Rating
300 V Rating
api-usa.com
Fax: 800-949-7502
2.75"
Hot Swappable
Plug-In Design
Quick Link
Power
115 VAC
115 VAC
115 VAC
115 VAC
115 VAC
115 VAC
115 VAC
115 VAC
115 VAC
API CLP1
© 08-19